High Accurancy CT PT Analyzer Price

Product Details
Customization: Available
After-sales Service: Life Time Support
Warranty: 1 Year or Extended
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
30000000 RMB
Plant Area
10000 square meters
  • High Accurancy CT PT Analyzer Price
  • High Accurancy CT PT Analyzer Price
  • High Accurancy CT PT Analyzer Price
  • High Accurancy CT PT Analyzer Price
  • High Accurancy CT PT Analyzer Price
Find Similar Products

Basic Info.

Model NO.
hm405
Output
0.1~125V (AC)
Current Output
0.001-5A(RMS)
Product Name
Current Transformer Testing Equipment
Power Supply
AC220V±10%,50Hz/60Hz±10%
Power Output
300va
Current Measurement: 
0~10A
Voltage Measurement
0~200 V
Turns Ratio Measurement
Turns Ratio Measurement:
Certificate
CE
Test Standards
IEC60044-1, IEC60044-6, GB1208, GB16847, C57.13
Gross Weight
39kgs
Measuring Size
740*500*420 mm
Net Weight
16kgs
Saved Data Groups
>1000groups
Transport Package
Wooden Box with Foam Inside
Specification
485mm*356mm*183mm
Trademark
HMDQ
Origin
Hubei, China(Mainland)
HS Code
9030820000
Production Capacity
500set/Month

Product Description

High Accurancy CT PT Analyzer Price

I. Summary:

CT PT analyzer is used to measure all kinds of current transformer and voltage transformer. It can calculate the ratio errors and phase angle errors of current transformer and voltage transformer at rated burden and working burden in one time test. The tester can automatically evaluate the test results according to the selected standard to determine whether the transformer is qualified.

II. Applications:

Tests for current transformer:
1) Excitation curve and parameters test
2) Turns ratio test
3) Ratio and phase error test
4) Polarity mark check
5) Winding resistance measurement
6) Secondary loop burden measurement
7) Error line curve test for protection CT
8) Transient CT parameters test
9) CT nameplate guess
10) Saturation hysteresis loop curve measurement
Tests for voltage transformer:
1) Turns ratio test
2) Ratio error and phase angle error test
3) Polarity test
4) Secondary burden test
5) Winding resistance test
High Accurancy CT PT Analyzer PriceHigh Accurancy CT PT Analyzer PriceHigh Accurancy CT PT Analyzer PriceHigh Accurancy CT PT Analyzer Price

III. 
Features:
1. Make evaluation for test results according to selected standards.
2. Make word report for test result.
3. Make word reports one time for multi-group test records on the PC.
4. Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test.
5. Compare excitation curves with saved excitation curves in the same window.
High Accurancy CT PT Analyzer Price

IV. Technical parameter

1 Test standards: IEC60044-1, IEC60044-6, GB1208, GB16847, C57.13
2 Power supply: AC220V±10%,50Hz/60Hz±10%
3 Power output: 0.1~125V (AC)
4 Current output: 0.001~5A(RMS)
5 Power output:300VA
6 Maximum knee voltage measurement; 45kv
7 Current measurement:
Range:0~10A (automatically change range in 0.1/0.4/2/10A)
Error <±0.1%+0.01%FS
8 Voltage measurement:
Range:0~200 V (automatically change range in 1V/10V/70V/200V)
Error < ±0.1%+0.01%FS
9 Turns ratio measurement:
Range :1~30000,
1~1000 error<0.05%
1000~2000 error<0.1%
2000~30000 error<0.2%
10 Phase measurement: error:±2min,resolution:0.01min
11 Coil resistance measurement:
Range:0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)
Error< 0.1%RDG+0.01%FS
Maximum resolution:0.1mΩ
12 Temperature measurement:-50~100 Celsius degree, error<3 Celsius degree
13 CT Secondary burden:
Range 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
Error <0.2%RDG+0.02%FS
Maximum resolution 0.001ohm
14 PT Secondary burden:
Range 0~80kohm (automatically change range in 800ohm/8kohm/80kohm)
Error <0.2%RDG+0.02%FS
Maximum resolution: 0.1ohm
15 Saved data groups:>1000groups
16 Work condition: Temperature:-10ºC~50ºC, moist:≤90%
17 Size: 485mm×356mm×183mm
18 Weight: <15Kg


V. Application field 


High Accurancy CT PT Analyzer Price
High Accurancy CT PT Analyzer Price

VI. Related products
 
High Accurancy CT PT Analyzer Price
High Accurancy CT PT Analyzer Price
High Accurancy CT PT Analyzer Price


High Accurancy CT PT Analyzer Price
High Accurancy CT PT Analyzer Price
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier