Packaging Details: | standard package for VLF hipot tester with tan delta measurement 40kV/60kV/80kV vlf high voltage generator cable testing equipment |
Delivery Detail: | vlf ac hipot tester 7-15days after order confirmed |
1) single connection structure (one booster) shall be adopted for ultra-low frequency with rated voltage less than or equal to 50kV; The ultra-low frequency greater than 50kV adopts series structure (two boosters are connected in series), which greatly reduces the overall weight and enhances the load capacity. Moreover, both boosters can be used alone to achieve multi-purpose of one machine.
3)Current and voltage data are directly sampled from the high voltage side, so the data is accurate.
4)Intelligent comprehensive protection function: there is no need to set the current and voltage protection value. The instrument can calculate the overvoltage and overcurrent protection value according to the capacitance of the test object and the test voltage value. It can also protect the sudden change of voltage and current, so it can capture the discharge. The protection action time is less than 20ms.
5)High voltage cable 150KV is adopted for output, which is safe and reliable.
6) Since the closed-loop negative feedback control circuit is adopted, the output has no capacity rise effect.
7) Dielectric loss(tgδ) measurement function (for buyer's option), which can measure the dielectric loss, capacitance and insulation resistance of the test object at the same time.
1) Rated output voltage: 30kv-90kv
2)Output frequency: automatic frequency conversion, range: 0.1Hz-0.01Hz
3)carrying capacity: see datesheet
4)Measurement accuracy: ≤ 3%
5)Voltage positive and negative peak error: ≤ 3%
6)Voltage waveform distortion: ≤ 3%
7)Operating conditions: indoor and outdoor; Temperature: - 10 ºC - + 40 ºC;
Humidity: ≤ 85% RH
8) Input power supply: 220V ± 5%, 50Hz/60Hz or customized. If the micro generator is used for power supply, the frequency conversion generator shall be used instead of the ordinary generator, because the unstable speed of the ordinary generator will make the boost abnormal and damage the instrument.
1.Can you provide the training for us?
Yes, we can provide free training for our client at our factory.
If you require the training on-site, we also can arrange accordingly.
We have 10 seasoned engineers who become our technical team, they flied many countries for client's installation and commissioning!
2.What is your after-sale service
We have 10 seasoned technical engineer as the after-sale service team.it is lead by our duty manager. We promise that our engineer can give answers within 1 hour and deal with equipment failure within 24 hours in time.
3.What's the warranty period ?
Our warranty period is one year .
The product can be replaced within 1 month, can be repaired for free charge for one year and maintenance for lifetime.
What is more, our warranty can be extended only charged small warranty fee.