Product Highlights

  • Wide Capacity Range: Rated capacity adjustable from 5kVA to 1000kVA to meet diverse testing needs.
  • High Voltage Output: Provides AC output voltage ranging from 0 to 1000kV for comprehensive insulation testing.
  • Low Partial Discharge: Ensures high precision with partial discharge under rated voltage less than 5PC.
  • Flexible Customization: Supports full customization, minor customization, and flexible options based on user requirements.
  • Multiple Structure Types: Available in four types: single phase iron shell and insulating clinger, both standard and series.
  • Advanced Console Safety: Equipped with over-current protection, emergency button, alarm bell, and voltage regulator protection.
  • Low No-Load Loss: Features efficient design with no-load loss between 0.2% and 0.35%.
  • Professional Application: Ideal for testing transformers, mutual inductors, and lightning arresters in labs and power departments.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Power-Frequency Partial Discharge Test Equipment/ Lab Equipment

Power-Frequency Partial Discharge Test Equipment/ Lab Equipment
Power-Frequency Partial Discharge Test Equipment/ Lab Equipment pictures & photos
Power-Frequency Partial Discharge Test Equipment/ Lab Equipment
Power-Frequency Partial Discharge Test Equipment/ Lab Equipment pictures & photos
Power-Frequency Partial Discharge Test Equipment/ Lab Equipment
Power-Frequency Partial Discharge Test Equipment/ Lab Equipment pictures & photos
Power-Frequency Partial Discharge Test Equipment/ Lab Equipment
Power-Frequency Partial Discharge Test Equipment/ Lab Equipment pictures & photos
Power-Frequency Partial Discharge Test Equipment/ Lab Equipment
Power-Frequency Partial Discharge Test Equipment/ Lab Equipment pictures & photos
Power-Frequency Partial Discharge Test Equipment/ Lab Equipment
Power-Frequency Partial Discharge Test Equipment/ Lab Equipment pictures & photos
Power-Frequency Partial Discharge Test Equipment/ Lab Equipment
  • Power-Frequency Partial Discharge Test Equipment/ Lab Equipment
  • Power-Frequency Partial Discharge Test Equipment/ Lab Equipment
    Power-Frequency Partial Discharge Test Equipment/ Lab Equipment
  • Power-Frequency Partial Discharge Test Equipment/ Lab Equipment
    Power-Frequency Partial Discharge Test Equipment/ Lab Equipment
  • Power-Frequency Partial Discharge Test Equipment/ Lab Equipment
    Power-Frequency Partial Discharge Test Equipment/ Lab Equipment
  • Power-Frequency Partial Discharge Test Equipment/ Lab Equipment
    Power-Frequency Partial Discharge Test Equipment/ Lab Equipment
  • Power-Frequency Partial Discharge Test Equipment/ Lab Equipment
    Power-Frequency Partial Discharge Test Equipment/ Lab Equipment
  • Power-Frequency Partial Discharge Test Equipment/ Lab Equipment
    Power-Frequency Partial Discharge Test Equipment/ Lab Equipment

Find Similar Products

Product Description

Product Description

 

Power Frequency Partial Discharge Testing Equipment /hipot tester

Power Frequency Partial Discharge Testing Equipment /hipot tester is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer, mutual inductor and lightning arresters. It widely used in electrical manufacturing, power operation departments, research institutes and universities.

HM-YDQW HV Test Equipment 150kVA/280kV Power Frequency Partial Discharge Testing Equipemtn Composition.
1.Testing transformer
2.Voltage Divider (concurrently as coupling capacitor)
3.Current Limiting Resistors
4.Power Isolation Filter
5.Console
6.Limb voltage regulator ( built-in Console)

Function Of The Console
The Console is equipped with over-current protection function, upper and lower voltage function, voltage withstand time recording, protection function, emergency button, alarm bell and door linkage.
The Console is equipped with capacitance voltage divider measuring voltmeter (digital
three-and-a-half), transformer primary winding ammeter and voltmeter.
The Console is equipped with upper and lower voltage regulator protection.
Power of Console is single phase power ;Running time: same as Testing Transformer.
Product Parameters

 


Power Frequency Partial Discharge Testing Equipment /Hipot Tester
Main Parameter:

 
Rated Capacity 5-1000kVA Impedance Voltage 10%
Input Voltage AC 220V/AC 380V Output Voltage Waveform Power frequency, sine wave
Output Voltage AC 0-1000kV Surface Temperature Oil immersed:<55ºC
Gas: <50ºC
Partial Discharge Under rated voltage≤5PC No-load Loss 0.2%-0.35%
Insulation Mode Oil, Gas Allowed Continuous Operation Time 1min as per

Remark:Can be customied according to  user's needs.

Power-Frequency Partial Discharge Test Equipment/ Lab Equipment


Power Frequency Partial Discharge Testing Equipment /hipot tester
According to structure , the device can be divided into four type: single phase iron shell type,
single phase iron shell series type, single phase insulating clinger type and single phase insulating clinger series type. Usually single phase iron shell type is suitable for the occasions where voltage capacity is low and easy to carry , or the equipment is fixed and its voltage capacity is high but with low requirement for partial discharge . Single phase insulating clinger type is usually suitable for the occasions where the requirement of partial discharge is high, but low voltage and fixed. Single phase insulating clinger series type is mainly used for the occasions where the requirement of partial discharge is high,and high voltage,large capacity and easy to carry. All above four type can be select by user's requirement.

Power-Frequency Partial Discharge Test Equipment/ Lab EquipmentPower-Frequency Partial Discharge Test Equipment/ Lab Equipment

Power-Frequency Partial Discharge Test Equipment/ Lab Equipment
Power-Frequency Partial Discharge Test Equipment/ Lab Equipment
 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR259015". Items marked "verified" are certified.

Watch Video
Watch Video
Wuhan Goldhome Hipot Electrical Co., Ltd.
Wuhan Goldhome Hipot Electrical Co., Ltd.
Wuhan Goldhome Hipot Electrical Co., Ltd.
Wuhan Goldhome Hipot Electrical Co., Ltd.
Wuhan Goldhome Hipot Electrical Co., Ltd.
Wuhan Goldhome Hipot Electrical Co., Ltd.
Wuhan Goldhome Hipot Electrical Co., Ltd.
Wuhan Goldhome Hipot Electrical Co., Ltd.

About Our Factory & Business Background

Address
No. A25-1 Huading Industrial Park, Hannan District, Wuhan, Hubei, China
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shanghai Port; Ningbo Port; Shenzhen Port; Guangzhhou Port
verified Minimum Order Quantity
1 Set
verified Supply Chain Partners
10

Our Production Capability & Technical Expertise

Main Products
AC Resonant Test System, AC/DC Hipot Tester, Circuit Breaker Analyzer, Hv Test Set, Power Frequency Hipot Tester, Transformer Tester, AC Dielectric Test Set, Partial Discharge Test Set, High Voltage Test Set, Primary Current Injection Test Set
verified Production Lines
4
verified Production Machines
Cutting Machine, Lathe, Drilling Machine, Milling Machine, Welding Machine, Wire Winding Machine
verified QA/QC inspectors
2 people
verified Inspection Type for Finished Products
100% inspection(Visual inspection & Function inspection)
verified Inspection Method for Finished Products
Have instructions and uniformly followed
verified Customization Options
Customization from Samples, Customization from Designs, Full Customization, Minor Customization, Flexible customization
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
3 people
verified Traceability of Raw Materials
Yes
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Export Year
17 Years
verified Main Markets
North America, South America, Europe, Southeast Asia/ Mideast
verified Annual Export Revenue
12,540,865 RMB
verified Number of Foreign Trading Staff
3
verified Overseas Agent/Branch
No
verified New Products Launched in Last year
Yes

FAQ

What is the rated capacity range of the equipment?
The rated capacity ranges from 5kVA to 1000kVA, allowing for flexible selection based on specific testing requirements.
What is the maximum output voltage?
The equipment provides an AC output voltage ranging from 0 to 1000kV.
Is the product customizable?
Yes, the product supports full customization, minor customization, and flexible customization based on user samples or designs.
What types of structures are available?
There are four types: single phase iron shell type, single phase iron shell series type, single phase insulating clinger type, and single phase insulating clinger series type.
What is the partial discharge level under rated voltage?
The partial discharge is less than 5PC under rated voltage, ensuring high precision and reliability.
What safety features does the console have?
The console includes over-current protection, upper and lower voltage protection, emergency button, alarm bell, and door linkage.
What is the no-load loss percentage?
The no-load loss is between 0.2% and 0.35%, indicating high energy efficiency.
What is the minimum order quantity?
The minimum order quantity is 1 set.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now