• No Partial Discharge Voltage Divider Non Partial Power Frequency Testing Transformer Pd-Free Test Transformer
  • No Partial Discharge Voltage Divider Non Partial Power Frequency Testing Transformer Pd-Free Test Transformer
  • No Partial Discharge Voltage Divider Non Partial Power Frequency Testing Transformer Pd-Free Test Transformer
  • No Partial Discharge Voltage Divider Non Partial Power Frequency Testing Transformer Pd-Free Test Transformer
  • No Partial Discharge Voltage Divider Non Partial Power Frequency Testing Transformer Pd-Free Test Transformer

No Partial Discharge Voltage Divider Non Partial Power Frequency Testing Transformer Pd-Free Test Transformer

Type: Universal Testing Machine
Display: Digital
Power Source: AC220V
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
No Partial Discharge Voltage Divider Non Partial Power Frequency Testing Transformer Pd-Free Test Transformer pictures & photos
No Partial Discharge Voltage Divider Non Partial Power Frequency Testing Transformer Pd-Free Test Transformer
US $20,200-100,200 / Set
Min. Order: 1 Set
Diamond Member Since 2018

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory

Basic Info.

Model NO.
HM-YDWQ
Frequency
50Hz
Phase
Single Phase
Partial Discharge
1-3PC
Output Voltage
0-280kv
Dielectric Loss
<0.3%
Rated Capacity
150kVA
Output Voltage(Customized)
AC 0-1000kv
Rated Capacity(Customized)
5-1000kVA
Transport Package
Wooden Box with Foam Inside
Specification
800 (L) * 710 (W) * 1380mm (H)
Trademark
HMDQ
Origin
Hubei, China(Mainland)
HS Code
9030339000
Production Capacity
50sets/Month

Product Description

High Voltage Partial Discharge Testing Machine /Pd-Free Test Transformer

High Voltage Partial Discharge Testing Machine /Pd-Free Test Transformer is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer, mutual inductor and lightning arresters. It widely used in electrical manufacturing, power operation departments, research institutes and universities.

HM-YDQW 150kVA/280kV High Voltage Partial Discharge Testing Machine Composition.
1.Testing transformer
2.Voltage Divider (concurrently as coupling capacitor)
3.Current Limiting Resistors
4.Power Isolation Filter
5.Console
6.Limb voltage regulator ( built-in Console)


Function Of The Console
The Console is equipped with over-current protection function, upper and lower voltage function, voltage withstand time recording, protection function, emergency button, alarm bell and door linkage.
The Console is equipped with capacitance voltage divider measuring voltmeter (digital
three-and-a-half), transformer primary winding ammeter and voltmeter.
The Console is equipped with upper and lower voltage regulator protection.
Power of Console is single phase power ;Running time: same as Testing Transformer.


High Voltage Partial Discharge Testing Machine /Pd-Free Test Transformer
Main Parameter:
 
Rated Capacity 5-1000kVA Impedance Voltage 10%
Input Voltage AC 220V/AC 380V Output Voltage Waveform Power frequency, sine wave
Output Voltage AC 0-1000kV Surface Temperature Oil immersed:<55ºC
Gas: <50ºC
Partial Discharge Under rated voltage≤5PC No-load Loss 0.2%-0.35%
Insulation Mode Oil, Gas Allowed Continuous Operation Time 1min as per

Remark:Can be customied according to  user's needs.

No Partial Discharge Voltage Divider Non Partial Power Frequency Testing Transformer Pd-Free Test Transformer
High Voltage Partial Discharge Testing Machine /Pd-Free Test Transformer

According to structure , the device can be divided into four type: single phase iron shell type,
single phase iron shell series type, single phase insulating clinger type and single phase insulating clinger series type. Usually single phase iron shell type is suitable for the occasions where voltage capacity is low and easy to carry , or the equipment is fixed and its voltage capacity is high but with low requirement for partial discharge . Single phase insulating clinger type is usually suitable for the occasions where the requirement of partial discharge is high, but low voltage and fixed. Single phase insulating clinger series type is mainly used for the occasions where the requirement of partial discharge is high,and high voltage,large capacity and easy to carry. All above four type can be select by user's requirement.



No Partial Discharge Voltage Divider Non Partial Power Frequency Testing Transformer Pd-Free Test Transformer
No Partial Discharge Voltage Divider Non Partial Power Frequency Testing Transformer Pd-Free Test Transformer


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
No Partial Discharge Voltage Divider Non Partial Power Frequency Testing Transformer Pd-Free Test Transformer pictures & photos
No Partial Discharge Voltage Divider Non Partial Power Frequency Testing Transformer Pd-Free Test Transformer
US $20,200-100,200 / Set
Min. Order: 1 Set
Diamond Member Since 2018

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Registered Capital
30000000 RMB
Plant Area
10000 square meters