Mobile Variable Frequency AC Resonant Test System with Partial Discharge 30~300Hz

Product Details
Customization: Available
After-sales Service: Life Time Support
Warranty: 1 Year or Extended

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
30000000 RMB
Plant Area
10000 square meters
  • Mobile Variable Frequency AC Resonant Test System with Partial Discharge 30~300Hz
  • Mobile Variable Frequency AC Resonant Test System with Partial Discharge 30~300Hz
  • Mobile Variable Frequency AC Resonant Test System with Partial Discharge 30~300Hz
  • Mobile Variable Frequency AC Resonant Test System with Partial Discharge 30~300Hz
  • Mobile Variable Frequency AC Resonant Test System with Partial Discharge 30~300Hz
  • Mobile Variable Frequency AC Resonant Test System with Partial Discharge 30~300Hz
Find Similar Products

Basic Info.

Model NO.
HMCXZ
Accuracy Grade
RMS 1.5
Display
Digital
Control
Controller or Computer
Power Source
220V/380V,10 %Single Phase, 50Hz
Frequency
20Hz-300Hz
Waveform
Sine
Protection
Over-Current, Over-Voltage,Flash-Over
Mode
Automatic and Manual Operation Mode
Print
Support
Tested Object
Cable, Gis, Transformer, Gil,Ect
Test Time
1hours or Customized
Using Place
Outdoors or Indoors
Partial Discharge
PC Less Than 10PC Support
Certificate
CE or Any Other Required
Cabliration Report
Factory Report or The Third -Party Support
Max Test Voltage
up to 10000kv or Higher
Max Capacity
up 10000kVA or Higher
Product Name
AC Resonant Test System
Calibration
Support Calibration
Transport Package
Wooden Box with Foam Inside
Specification
customize
Trademark
HMDQ
Origin
Hubei, China(Mainland)
HS Code
9030390000
Production Capacity
500sets/Month

Product Description

Mobile Variable frequency AC Resonant test system with partial discharge  30~300hZ
 
I. Product description
The Partial Discharge High Voltage Variable Frequency Resonance Test System is composed of partial discharge variable frequency power, partial discharge exciting transformer, pd free HV reactor and pd free capacitive voltage divider. The partial discharge level could be controlled within 5pC at rated voltage . The regular ac resonant test set is made up of variable frequency power source, excitation transformer, HV reactor and capacitive voltage divider. The capacitor and reactor of test object formed a serial resonance connection. The voltage divider is in serial connection with the test object and used for measuring the resonance voltage and acting as the overvoltage protection signal. The frequency modulation power output is coupled to series resonance circuit via excitation transformer to provide the exciting power.
This high voltage test equipment  does not have a problem of large starting current. The power supply with small capacity is capable of fulfilling the test equivalent to 30 to 60 times of the power supply. This greatly solved the problem of poor capacity of test power at site.

Mobile Variable Frequency AC Resonant Test System with Partial Discharge 30~300Hz


Hot tag: ac resonant test system.high voltage resonant test system;withstanding voltage tester;ac high voltage test;withstanding voltage tester;ac high voltage test set;ac high pot tester;high voltage dielectric tester;resonant test set;resonant test system.
II. Schematic diagram
Mobile Variable Frequency AC Resonant Test System with Partial Discharge 30~300Hz
III.  Resonant Test System main specification 

1.Rated output voltage: based on different test objects, max up to 10000kV.
2.Output frequency: 20- 300Hz.
3.Waveform: pure sine wave, THD <1.0%.
4.Max. capacity: Max up to 20000kVA
5. Duty Cycle: Continuous working time 60 mins at full power output.
6. Frequency adjustment sensitivity: 0.1Hz, instability <0.05%.
7. Power Supply: 380/220V ± 15%/50Hz ± 5%.
8. Partial discharge level:Less than 5 pC, If the voltage is up to 600kV or Above, less than 10pC.
Mobile Variable Frequency AC Resonant Test System with Partial Discharge 30~300Hz

VI. Application 
Mobile Variable Frequency AC Resonant Test System with Partial Discharge 30~300Hz

V. Cases at site
Mobile Variable Frequency AC Resonant Test System with Partial Discharge 30~300Hz

FVI. FAQ
1.Can you provide the training for us?
Yes, we can provide free training for our client at our factory.
If you require the training on-site, we also can arrange accordingly.
We have 10 seasoned engineers who become our technical team, they flied many countries for client's installation and commissioning!

2.What is your after-sale service
We have 10 seasoned technical engineer as the after-sale service team.it is lead by our duty manager. We promise that our engineer can give answers within 1 hour and deal with equipment failure within 24 hours in time.

3.What's the warranty period ?
Our warranty period is two year .
The product can be replaced within 1 month, can be repaired for free charge  for one year and maintenance for lifetime.
What is more, our warranty can be extended only charged small warranty fee.


Mobile Variable Frequency AC Resonant Test System with Partial Discharge 30~300Hz
VII.Company profile

Wuhan Goldhome Hipot Electrical Co.,ltd is one of the earliest enterprises specially in develop, design and manufacture high-voltage testing equipments in China.  In 2016, merged with Wuhan Sangao Electric Co., Ltd. , realize advantageous complementarities and resources reorganization , develop into a joint-stock enterprise.Closely cooperated with the professors from State Grid Power Science Research Institute, Electrical Engineering Colleage of Wuhan University (formerly Wuhan University of Water Resources and Electric Power) and other scientific research institutions . Now it has become a high-tech enterprise integrating R&D, production, marketing and installation.

Goldhome Hipot will always stick to the leading science and technology, quality first,  heart-to-heart business and win-win cooperation!


Mobile Variable Frequency AC Resonant Test System with Partial Discharge 30~300HzMobile Variable Frequency AC Resonant Test System with Partial Discharge 30~300Hz



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier