Partial Discharge Test Cables Acceptance Criteria

Product Details
Customization: Available
Type: Universal Testing Machine
Accuracy Grade: 1.5
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
30000000 RMB
Plant Area
10000 square meters
  • Partial Discharge Test Cables Acceptance Criteria
  • Partial Discharge Test Cables Acceptance Criteria
  • Partial Discharge Test Cables Acceptance Criteria
  • Partial Discharge Test Cables Acceptance Criteria
  • Partial Discharge Test Cables Acceptance Criteria
  • Partial Discharge Test Cables Acceptance Criteria
Find Similar Products

Basic Info.

Model NO.
HMYDQW
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Digital
Control
Electrical
Weight
150kg
Power Source
AC380V
Frequency
50Hz
Phase
Single Phase
Partial Discharge
1-3PC
Output Voltage
0-280kv
Dielectric Loss
<0.3%
Noise
≤60dB
Waveform Deviation Factor
<3%
Rated Capacity
150kVA
Output Voltage(Customized)
AC 0-1000kv
Rated Capacity(Customized)
5-1000kVA
Insulation Medium
Oil-Type
Transport Package
Wooden Box with Foam Inside
Specification
800 (L) * 710 (W) * 1380mm (H)
Trademark
HMDQ
Origin
Hubei, China(Mainland)
HS Code
9030339000
Production Capacity
50sets/Month

Product Description

Power Frequency Partial Discharge Testing Equipment /hipot tester

Power Frequency Partial Discharge Testing Equipment /hipot tester is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer, mutual inductor and lightning arresters. It widely used in electrical manufacturing, power operation departments, research institutes and universities.

HM-YDQW HV Test Equipment Power Frequency Partial Discharge Testing Equipemtn Composition.
1.Testing transformer
2.Voltage Divider (concurrently as coupling capacitor)
3.Current Limiting Resistors
4.Power Isolation Filter
5.Console
6.Limb voltage regulator ( built-in Console)

Function Of The Console
The Console is equipped with over-current protection function, upper and lower voltage function, voltage withstand time recording, protection function, emergency button, alarm bell and door linkage.
The Console is equipped with capacitance voltage divider measuring voltmeter (digital
three-and-a-half), transformer primary winding ammeter and voltmeter.
The Console is equipped with upper and lower voltage regulator protection.
Power of Console is single phase power ;Running time: same as Testing Transformer.

Power Frequency Partial Discharge Testing Equipment /Hipot Tester
Main Parameter:

 
Rated Capacity 5-1000kVA Impedance Voltage 10%
Input Voltage AC 220V/AC 380V Output Voltage Waveform Power frequency, sine wave
Output Voltage AC 0-1000kV Surface Temperature Oil immersed:<55ºC
Gas: <50ºC
Partial Discharge Under rated voltage≤5PC No-load Loss 0.2%-0.35%
Insulation Mode Oil, Gas Allowed Continuous Operation Time 1min as per

Remark:Power Frequency Partial Discharge Testing Equipment can be customied according to  user's needs.


Take 150kVA/280kVA for example, one of the components parameter as below
Technical Parameter for Test Transformer
Phase :single phase
Frequency:50Hz
Rated capacity:150kVA
Input voltage:0.4kV
Input current:375A       
Output voltage:0~280kV
Output current: 0.53A
Waveform deviation factor:≤3%
Measurement winding voltage ratio:1000:1
Insulation level: low voltage input terminal to ground power frequency voltage withstand level 5kV/1min
Dielectric loss: <0.3%
Noise:≤60dB
Partial discharge: 0-250kV ,the partial discharge is ≤1-3PC; 0-280kV, the partial discharge is ≤3-5pc
Running time: under rated voltage and current,start form environment temperature,can run 30min.
under 2/3 rated voltage and current, continuous running.
Single test transformer impedance :  3%-12%
Waveform deviation factor: <3%

Remark:Inquriy All parameter of the whole test equipment,please contact us.

Partial Discharge Test Cables Acceptance Criteria
Power Frequency Partial Discharge Testing Equipment /hipot tester

According to structure , the device can be divided into four type: single phase iron shell type,
single phase iron shell series type, single phase insulating clinger type and single phase insulating clinger series type. Usually single phase iron shell type is suitable for the occasions where voltage capacity is low and easy to carry , or the equipment is fixed and its voltage capacity is high but with low requirement for partial discharge . Single phase insulating clinger type is usually suitable for the occasions where the requirement of partial discharge is high, but low voltage and fixed. Single phase insulating clinger series type is mainly used for the occasions where the requirement of partial discharge is high,and high voltage,large capacity and easy to carry. All above four type can be select by user's requirement.

Similar Product
Partial Discharge Test Cables Acceptance Criteria



Partial Discharge Test Cables Acceptance Criteria

Partial Discharge Test Cables Acceptance Criteria


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier