• Secondary Injection Tester Secondary Current Injection Relay Test Set
  • Secondary Injection Tester Secondary Current Injection Relay Test Set
  • Secondary Injection Tester Secondary Current Injection Relay Test Set
  • Secondary Injection Tester Secondary Current Injection Relay Test Set
  • Secondary Injection Tester Secondary Current Injection Relay Test Set
  • Secondary Injection Tester Secondary Current Injection Relay Test Set

Secondary Injection Tester Secondary Current Injection Relay Test Set

Type: Strength Testing Machine
Maxcapacity: No
Accuracy Grade: 0.5
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Secondary Injection Tester Secondary Current Injection Relay Test Set pictures & photos
Secondary Injection Tester Secondary Current Injection Relay Test Set
US $2,000-6,000 / Piece
Min. Order: 1 Piece
Diamond Member Since 2018

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory

Basic Info.

Model NO.
HM1200
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
LCD
Control
Computer Control
Power Source
AC220V
Oil Cylinder Position
No
Time Measuring Range
0.1ms - 9999s
Accuracy of Measurement
<0.1ms
Phase Voltage / Line Phase Output Power
70va / 140va
Harmonic Time
1-20
Frequency Range (Fundamental)
20-1000Hz
Output Precision
0.5 Degree
Product Name
Production Relay Tester
Work Temperature
-10°c~ 50°c
Transport Package
Wooden Box with Foam Inside
Specification
customize
Trademark
GDHM
Origin
Hubei, China(Mainland)
HS Code
9030820000
Production Capacity
200sets/Month

Product Description

 Secondary Injection Tester Secondary Current Injection Relay Test Set

Main features

1.  Flexible combination of voltage and current output
Six phase voltage and six phase current can be output, which has made it is possiable to be any combition, such as the output mode of the combination of conventional four phase current and three-phase current, six phase voltage mode, six phase current mode and 12 phase output mode. It not only can be compatible with the traditional way of various tests, but also can conveniently carry out differential test of three-phase transformer.
2. Operation mode
The device is directly connected with a computer or a desktop computer, which is convenient and efficient and stable performance.
3. A new hi-fi linear power amplifier 
The output port has always insisted on using the modular linear power amplifier instead of the switching power amplifier, which has the high fidelity and high reliability function and excellent performance. High-mid frequency will not be produced to disturb the test, also ensure the smoothing accuracy of waveform produced by the whole course of the high current to the tiny current is excellent.
4. High performance Mainframe
The output part adopts DSP control, which has fast operation, real-time digital signal processing capability, wide bandwidth and high resolution D/A conversion control. The output waveform has the features of high precision, small distortion and good linearity. With using a large number of advanced technology and precision components and materials and the structure of professional design, the device has the features of small volume, light weight, full function, easy to carry, boot can work, flow test is very convenient.
5. Powerful software function
It can complete all kinds of high automatic validation work which is large and complex. It can also conveniently test and scan protection setting, playback of fault, real-time store test data, display vector, online print report and so on. Besides, six-phase current can facilitate the test of three-phase differential protection.
6. Independent DC power output
An 110V and 220V adjustable DC power is designed to supply output.
7. Complete interface
The device with USB communication port can communicate with the computer and other external devices.
8. Perfect self-protection function
With reasonable design of the heat dissipation structure and the reliable and perfect hardware protection measures, it has the power soft start function and the software of the fault self-diagnosis and the output latch function.


Main  Parameter

Type  
Current channel number Standard six phase
Voltage channel number Standard six phase
AC current output range 30A / phase or 180A (six phase parallel)
DC current output range 10A DC /phase
AC voltage output range 120V AC /phase
DC voltage output range 160V DC / phase

Nominal parameter

AC current output
The virtual value of each phase output when six phase current output  0~30A    output precision   0.1 grade
The virtual value of each phase output when three phase current output  0~60A
The virtual value of six phase parallel current output                    0~180A
The allowed virtual value when the phase current work long time        10A
The maximum output power of phase current                         450VA
The maximum output power when six phase parallel current output      1000VA
The allowed working time when six phase parallel current maximum output    10s
Frequency range(fundamental wave)                             0~1000Hz
Harmonic order                                                   0~20 

DC current output
Current output            0~±10A / phase       output precision   0.2 grade
The maximum load volatage output                                 20V

AC voltage output
The virtual value of phase voltage output  0~120V    output precision   0.1 grade
The virtual value of line voltage output                               0~240V
The output power of phase voltage/ line voltage                      80VA / 100VA
Frequency range(fundamental wave)                             0~1000Hz
Harmonic order                                                   0~20 

DC voltage output
The output amplitude of phase voltage  0~±160V   output precision  0.2 grade
The output amplitude of line voltage                                0~±320V
The output power of phase voltage/ line voltage                      70VA / 140VA

Input and output
8 channels input
Free contact                                             1~20mA,24V
Electric potential contacts           "0":0 ~ +6V; "1":+11 V ~ +250 V
4 channels output                              DC:220 V/0.2 A;AC:220 V/0.5 A

Time measurment range
0.1ms ~ 9999s ,    measurement accuracy <0.1ms

Secondary Injection Tester Secondary Current Injection Relay Test Set

Secondary Injection Tester Secondary Current Injection Relay Test Set

Secondary Injection Tester Secondary Current Injection Relay Test Set

 

Secondary Injection Tester Secondary Current Injection Relay Test Set
Secondary Injection Tester Secondary Current Injection Relay Test Set

 

Send your message to this supplier

*From:
*To:
avatar Ms. Goldhome
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now