• Variable Frequency Mode CT / PT Analyzer with High Accuracy 0.05%
  • Variable Frequency Mode CT / PT Analyzer with High Accuracy 0.05%
  • Variable Frequency Mode CT / PT Analyzer with High Accuracy 0.05%
  • Variable Frequency Mode CT / PT Analyzer with High Accuracy 0.05%
  • Variable Frequency Mode CT / PT Analyzer with High Accuracy 0.05%
  • Variable Frequency Mode CT / PT Analyzer with High Accuracy 0.05%

Variable Frequency Mode CT / PT Analyzer with High Accuracy 0.05%

Type: CT/PT Analyzer
Load Way: Electronic Load
Loading Method: Dynamic Load
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Variable Frequency Mode CT / PT Analyzer with High Accuracy 0.05% pictures & photos
Variable Frequency Mode CT / PT Analyzer with High Accuracy 0.05%
US $2,000-6,000 / Piece
Min. Order: 1 Piece
Diamond Member Since 2018

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory

Basic Info.

Model NO.
hm405
Display
Digital
Weight
<15kg
Power Source
AC220V
Maximum Knee Voltage Measurement
45kv
Output
0.1~125V (AC)
Current Output
0.001-5A(RMS)
Product Name
Current Transformer Testing Equipment
Power Supply
AC220V±10%,50Hz/60Hz±10%
Power Output
300va
Current Measurement: 
0~10A
Voltage Measurement
0~200 V
Turns Ratio Measurement
Turns Ratio Measurement:
Transport Package
Wooden Box with Foam Inside
Specification
485mm*356mm*183mm
Trademark
GDHM
Origin
Hubei, China(Mainland)
HS Code
9030820000
Production Capacity
500set/Month

Product Description

Variable Frequency Mode CT / PT Analyzer  with High Accuracy 0.05%

Summary:

CT PT analyzer is used to measure all kinds of current transformer and voltage transformer. It can calculate the ratio errors and phase angle errors of current transformer and voltage transformer at rated burden and working burden in one time test. The tester can automatically evaluate the test results according to the selected standard to determine whether the transformer is qualified.

 

Applications:

Tests for current transformer:
1) Excitation curve and parameters test
2) Turns ratio test
3) Ratio and phase error test
4) Polarity mark check
5) Winding resistance measurement
6) Secondary loop burden measurement
7) Error line curve test for protection CT
8) Transient CT parameters test
9) CT nameplate guess
10) Saturation hysteresis loop curve measurement
Tests for voltage transformer:
1) Turns ratio test
2) Ratio error and phase angle error test
3) Polarity test
4) Secondary burden test
5) Winding resistance test


Variable Frequency Mode CT / PT Analyzer with High Accuracy 0.05%
Variable Frequency Mode CT / PT Analyzer with High Accuracy 0.05%
 

Features:

1. Make evaluation for test results according to selected standards.
2. Make word report for test result.
3. Make word reports one time for multi-group test records on the PC.
4. Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test.
5. Compare excitation curves with saved excitation curves in the same window.

 

Technical parameter

1 Test standards: IEC60044-1, IEC60044-6, GB1208, GB16847, C57.13
2 Power supply: AC220V±10%,50Hz/60Hz±10%
3 Power output: 0.1~125V (AC)
4 Current output: 0.001~5A(RMS)
5 Power output:300VA
6 Maximum knee voltage measurement; 45kv
7 Current measurement:
Range:0~10A (automatically change range in 0.1/0.4/2/10A)
Error <±0.1%+0.01%FS
8 Voltage measurement:
Range:0~200 V (automatically change range in 1V/10V/70V/200V)
Error < ±0.1%+0.01%FS
9 Turns ratio measurement:
Range :1~30000,
1~1000 error<0.05%
1000~2000 error<0.1%
2000~30000 error<0.2%
10 Phase measurement: error:±2min,resolution:0.01min
11 Coil resistance measurement:
Range:0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)
Error< 0.1%RDG+0.01%FS
Maximum resolution:0.1mΩ
12 Temperature measurement:-50~100 Celsius degree, error<3 Celsius degree
13 CT Secondary burden:
Range 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
Error <0.2%RDG+0.02%FS
Maximum resolution 0.001ohm
14 PT Secondary burden:
Range 0~80kohm (automatically change range in 800ohm/8kohm/80kohm)
Error <0.2%RDG+0.02%FS
Maximum resolution: 0.1ohm
15 Saved data groups:>1000groups
16 Work condition: Temperature:-10ºC~50ºC, moist:≤90%
17 Size: 485mm×356mm×183mm
18 Weight: <15Kg
Variable Frequency Mode CT / PT Analyzer with High Accuracy 0.05%
 

Variable Frequency Mode CT / PT Analyzer with High Accuracy 0.05%
Variable Frequency Mode CT / PT Analyzer with High Accuracy 0.05%
 

Send your message to this supplier

*From:
*To:
avatar Ms. Goldhome
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now