10kv 12kv Transformer Tan Delta Test Device

Product Details
Customization: Available
After-sales Service: Life Long Support
Warranty: 1 Year
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
30000000 RMB
Plant Area
10000 square meters
  • 10kv 12kv Transformer Tan Delta Test Device
  • 10kv 12kv Transformer Tan Delta Test Device
  • 10kv 12kv Transformer Tan Delta Test Device
  • 10kv 12kv Transformer Tan Delta Test Device
  • 10kv 12kv Transformer Tan Delta Test Device
  • 10kv 12kv Transformer Tan Delta Test Device
Find Similar Products

Basic Info.

Model NO.
HM5006
Display
LCD
Weight
28kg
Power Source
180V-270VAC, 50Hz/60Hz+-1%
Relative Humidity
<90%
Transport Package
Wooden Box with Foam Inside
Specification
460mm*360mm*350mm.
Trademark
hmdq
Origin
Hubei, China(Mainland)
HS Code
9030390000
Production Capacity
500sets/Month

Packaging & Delivery

Package Size
53.00cm * 37.00cm * 31.00cm
Package Gross Weight
30.000kg

Product Description

10kv 12kv transformer tan delta test device

Summary


Dielectric loss measurement is a basic method in insulation test and effectively detect damp, degradation and partial defect of insulation of electrical equipment. This method is widely used in electric manufacturing, electric equipment installation, connection and preventive test. Measurement on dielectric loss of transformer, mutual inductor, reactor, capacitor, bushing and arrester is the most basic method to test their insulation property.**** fully-automatic anti-interference dielectric loss tester breaks through the traditional bridge testing method and adopts variable frequency power technology, single chip and modernized electrical technology to carry out automatic frequency shift, analog-to-digital conversion and data computing. It features strong anti-interference capacity, high test speed, high precision, automatic digitization and easy operation. It adopts high-power switching power supply, which outputs 45Hz and 55Hz pure sine wave and automatically increase the voltage to a maximum value 10 KV. It can filter 50Hz interference automatically, and it is applicable to the site test of substation and other places with large electromagnetic interference. This methods is extensively applied in dielectric loss measurement of transformer, mutual inductor, reactor, bushing, capacitor, arrester and others equipments in power industry.
10kv 12kv Transformer Tan Delta Test Device10kv 12kv Transformer Tan Delta Test Device10kv 12kv Transformer Tan Delta Test Device10kv 12kv Transformer Tan Delta Test Device

 

Performance features
1. The instrument adopts complex number current method to measure capacitance, dielectric loss and other parameters. The measured result is highly accurate and it is easy to realize automatic measurement.  

2. The instrument adopts variable frequency technology to eliminate 50Hz/60Hz power frequency interference. So a reliable data will be reachable even under the strong electromagnetic interference.  
3. The instrument adopts large screen LCD . In the process of testing, Chinese menu prompt is visualized and easy to operate.
4. The instrument is easy to operate and the measuring process is controlled by microprocessor. Once a suitable measuring method is selected, the data measurement will complete automatically under the control of microprocessor.
5. The instrument is designed to be an integrated model with reference capacitor and HV power supply in it, enables site test measurement and reduces site wiring.
7. The instrument is equipped with CVT testing function, which can achieve CVT self-exciting testing without external accessories and measure the capacitance and dielectric loss of C1 and C2 by at a time.
8. GST measurement adopts ivddv technology and avoids unstable data provided by previous GST measurement.
9. The instrument provides low voltage shell function of GST. When the bus of 220kV CVT is grounded, dielectric loss measurement can be conducted for C11 without removing 10 kV GST.
10. The instrument has a function of measuring high-voltage dielectric loss. It can carry out dielectric loss test with over 10kV with the help of voltage transformer or series resonance.
12. The instrument has a ground-fault protection function. In case that the instrument is not grounded or grounded incorrectly, the instrument will refuse to enter into normal procedure and output HV. As for the over-current protection function, it will protect the instrument from damage when the tested article is in a short circuit or breakdowns.
13. The instrument has a function of electric shock protection. When the instrument operator suffers an electric shock due to incaution, the instrument will cut off the HV immediately and thus ensure the security of operator.


Technical indicators

Accuracy: Cx: ±(reading×1%+1pF)
tgδ: ±(reading×1%+0.00040)
Anti-interference: Variable frequency anti-interference, the above accuracy can be reached under 200% interference. 
Capacitance range: Internal HV: 3pF~60000pF/10kV 60pF~1μF/0.5kV
 External HV: 3pF~1.5μF/10kV 60pF~30μF/0.5kV
 Resolution: Maximum 0.001pF, 4 valid figures. 
tgδ range:unlimited, 0.001% resolution, automatic identification for capacitance, inductance and resistance of three tested articles. 
Test current range: 10μA~1A
Internal HV: Set voltage range: 0.5~10kV
Maximum output current: 200mA
 Buck-bust method: continuous stepless regulation
 Test frequency: 45, 50, 55 single frequency 45/55Hz automatic dual variable frequency
Frequency accuracy: ±0.01Hz
External HV: In case of UST, maximum test current is 1A,and power frequency or variable frequency is 40-70Hz
In case of GST, maximum test current is 10kV/1A,
and power frequency or variable frequency is 40-70Hz
CVT self-exciting low voltage output: Output voltage 3~50V,
output current 3~30A
Measuring duration: About 40s, depending on measuring method
Input power supply: 180V~270VAC, 50Hz/60Hz±1%,
supplied by alternating current or generator
Computer interface: Standard RS232 interface
Printer: WH-A7 mini-type thermal printer
Environment temperature: -10ºC~50ºC
Relative humidity: <90%
Overall dimension:460×360×350mm
Weight:28kg


10kv 12kv Transformer Tan Delta Test Device
10kv 12kv Transformer Tan Delta Test Device
10kv 12kv Transformer Tan Delta Test Device
10kv 12kv Transformer Tan Delta Test Device

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier