60kv ac vlf Hipot Test Equipment
Product Advantage
1.VLF means 'Very Low Frequency' and 0.1Hz to 0.02Hz is considered to be very low frequency.
2.VLF HV Generator is suitable fortesting cables, transformers,switchgear,rotating machinery,and otherelectrical apparatus.
3.The product combines modern advanced digital variable frequency technology and micro computer control together, therefore, it can realize the full automatic voltage boost, stepdown, measurement and protection as well as the manual intervention in the process of automatic voltage boost. The full electronic design ensures the small size and light weight. The big LCD screen ensures the clear and visual display, and can display the output wave form. The printer outputs test reports. In addition.
Features
1)Data of current, voltage, wave form can be directly sampled at high voltage side, so the data is real and accurate.
2)Overvoltage protection: If the output exceeds the set limit of voltage, the instrument will shut-down to protect itself, the actuationtime is less than 20ms.
3)Overcurrent protection: it is high-low voltage dual protection in the design, the accurate shut-down protection can be made according to the set value at high voltage side;If the current on low voltage side exceeds the rated current, the instrument will take shut-down protection, the actuationtime are both less than 20ms.
4)A high voltage output protective resistor is provided in the voltage boost body in the design and this eliminates the need of additional protective resistor connected outside.
5)True sine wave output.
6)Storage of test results for later retrieval and print.
7)AC testing does not degrade good cable insulation.
8)Harmful space charges are not injected into the cable insulation.
9)No traveling waves are generated during testing.
10)Rugged and reliable design less prone to failure from transients.
Technical parameters
1. Input: 220 ± 10% Volts AC, 50/60 Hz, single phase.
2. Output-Voltage:See below table 1.
3. Output frequency: 0.1Hz, 0.05Hz, 0.02Hz.
4. Stability of frequency: Fluctuation < 0.5%
5. Measurement accuracy: ±3%.
6. Positive and negative voltage peak errors: ≤3%.
7. Voltage waveform distortion: ≤5%
8. Construction: In two units: Controller and Booster..
9. Ambient conditions of use: temperature Indoor and
outdoor : -10ºC to + 50ºC.
10. Humidity:≤85%
Type |
Output Voltage/Current |
Load Capacity |
Control Unit |
Booster |
Fuse Tube |
Frequency/ Capacitance |
Dim. (cm) |
Wt (kg) |
Dim. (cm) |
Wt (kg) |
VLF-30/1.1 |
30KV/29mA |
0.1Hz ≤ 1.1uF 0.05Hz ≤ 2.2uF 0.02Hz ≤ 5.5uF |
28×37×22 |
4 |
33×18×34 |
25 |
5A |
VLF-40/1.1 |
40KV/29mA |
0.1Hz ≤ 1.1uF 0.05Hz ≤ 2.2uF 0.02Hz ≤ 5.5uF |
28×37×22 |
4 |
35×20×36 |
45 |
6A |
VLF-50/1.1 |
50KV/59mA |
0.1Hz ≤ 1.1uF 0.05Hz ≤ 2.2uF 0.02Hz ≤ 5.5uF |
28×37×22 |
4 |
37×24×39 |
45 |
7A |
VLF-60/0.5 |
60KV/59mA |
0.1Hz ≤0.5uF 0.05Hz ≤ 1.0uF 0.02Hz ≤ 2.5uF |
28×37×22 |
4 |
33×18×34 33×18×34 |
25+45 |
10A |
VLF-70/0.5 |
70KV/59mA |
0.1 Hz,≤0.5µF 0.05Hz, ≤1.0µF 0.02Hz, ≤2.5µF |
28×37×22 |
4 |
33×18×34 35×20×36 |
25+45 |
10A |
VLF-80/0.5 |
80KV/59mA |
0.1 Hz,≤0.5µF 0.05Hz, ≤1.0µF 0.02Hz, ≤2.5µF |
28×37×22 |
4 |
33×18×34 37×24×39 |
25+45 |
12A |