• 60kv DC Hipot High Voltage Dielectric Test Set
  • 60kv DC Hipot High Voltage Dielectric Test Set
  • 60kv DC Hipot High Voltage Dielectric Test Set
  • 60kv DC Hipot High Voltage Dielectric Test Set
  • 60kv DC Hipot High Voltage Dielectric Test Set
  • 60kv DC Hipot High Voltage Dielectric Test Set

60kv DC Hipot High Voltage Dielectric Test Set

After-sales Service: Life Long Support
Warranty: 1 Year
Type: DC Hipot Tester
Accuracy Grade: 1
Weight: 13kg
Power Source: AC220V
Customization:
Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
HMZGF-120kVA/2mA
Over Voltage Rectify Accuracy
<=1.0%
Ripple Factor
<=0.5%
Output Voltage
60kv,100kv, 120kv,200kv
Leakage Current
2/3/5/10mA
Transport Package
Wooden Box with Foam Inside
Trademark
hmdq
Origin
Hubei, China(Mainland)
HS Code
9030390000
Production Capacity
500sets/Month

Product Description

60kv DC Hipot high voltage  Dielectric Test Set


Summary
Newly researched, designed, and manufactured according to "Common technical condition for portable DC HV generator" of China Industry Standard, the HMZGF series DC HV generator is a technology product of new era, suitable for DC HV test on zincoxidearrester, magnetic blow-out arrester, power cable, generator, transformer, and switch in electric power department, scientific research unit, railway station, power plant, chemical plant, etc., a optimal upgrading product in new era.
60kv DC Hipot High Voltage Dielectric Test Set60kv DC Hipot High Voltage Dielectric Test Set60kv DC Hipot High Voltage Dielectric Test Set60kv DC Hipot High Voltage Dielectric Test Set60kv DC Hipot High Voltage Dielectric Test Set


Technical parameters

Output voltage(kV):60

Output current (mA):5

Output power (W):300

Charging current (mA):7.5

Case weight (kg):13

Height of multivoltage tube (kg):4

HV polarity

Polarity of negative volt, zero voltage start, continuous adjustable

Work power

AC 220V±10%;50Hz

Voltage measuring accuracy

1.0%(full scale)±1character, max resolution 0.1%kV

Current measuring accuracy

1.0%(full scale)±1character, max resolution 0.1%uA

Over voltage rectify accuracy

≤0.5%

0.75 switch over accuracy

≤1.0%

Ripple factor

≤0.5%

Voltage stability

Random fluctuation, when voltage change of power supply±10% ≤0.5%

Work manner

Intermittent service; 30min of rated load;1.1 times of rated voltage use:10min

Temperature

-10ºC~40ºC

Relative humidity

When at 25ºC,no more than 85%(no condensation)

Altitude

Below 1500m