20 ~300 Hz Variable Frequency Series Resonance Test Set

Product Details
Customization: Available
After-sales Service: Suppor for Lifelong
Warranty: 12months or Extended

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
30000000 RMB
Plant Area
10000 square meters
  • 20 ~300 Hz Variable Frequency Series Resonance Test Set
  • 20 ~300 Hz Variable Frequency Series Resonance Test Set
  • 20 ~300 Hz Variable Frequency Series Resonance Test Set
  • 20 ~300 Hz Variable Frequency Series Resonance Test Set
  • 20 ~300 Hz Variable Frequency Series Resonance Test Set
  • 20 ~300 Hz Variable Frequency Series Resonance Test Set
Find Similar Products

Basic Info.

Model NO.
hmcxz
Type
Hv Test Set
Accuracy Grade
RMS 1.5
Display
Touch Screen
Power Source
220V/380V,10 %Single Phase, 50Hz
Product Name
AC Resonant Test System
Input Voltage
220V/380V
Frequency
20~300Hz
Pd Amount
Less Than 10PC
Parameter
Customized
Applicated
Gis,Cable, Transformer, Ect
Operation Mode
Automatic and Manual
Controlled
PC Controlled or Through Console
Structure
in Series or in Parallel
Display Screen
Touch Screen
Protection
Over-Current, Over-Voltage, Flashover Protection
Certificate
ISO, SGS, CE
Calibration Report
Factory Release Report
Transport Package
Wooden Box with Foam Inside
Trademark
HMDQ
Origin
Hubei, China(Mainland)

Product Description

20-300Hz Variable Frequency Series Resonance Ac Hipot dielectric breakdown Test System Device

Advantage
1) Placed way: the placement of variable frequency power for longitudinal and transverse, especially suitable for field operation and observe.
2) Shockproof protection: internal and external have special damping rubber support foot and protect aluminum boxes, which can effectively slow motion and lifting the bumpy transport the shock. Ensure the inverter power long-term stability and reliability.
3) Parameter display: touch or external mouse LCD interface display system.
Can show resonance voltage (namely test before setting goals voltage), test frequency, measure frequency, low-pressure voltage, low voltage electric current, voltage time, over-voltage protection, over-current protection, flash winding protection, phase booster and stage timing, operation mode switch, capacitor, inductance, frequency swap calculation, parameters, still can show inquiry on frequency curve, voltage curve can intuitivey judgment when trials resonance frequency accurately and stability.
4) Parameter Settings: big screen touch LCD backlit and external mouse directly in completing various parameters Settings. But on the initial frequency, termination frequency, starting voltage, phase booster and timing, measuring bleeder variable ratio, incentive change ratio, over-voltage protection, over-current protection, flash winding protection, test mode, capacitance inductance frequency swap calculation, parameter setting tips, and help parameters Settings or choice.
5) Test mode: touch screen and external mouse operation, there is automatic and semi-automatic, manual three operating status. With pressor, tuning (including manual, automatic), subsection pressurized and timing, running status, pattern switching, troubleshooting tips, capacitance inductance frequency swap computing functions, etc.
6) Protection function and information clew: having high-pressure over-voltage protection, low-pressure over-current, over-current protection, as well as detuning protection, zero, shem winding protection, emergency stop, undervoltage protection multiple protection function.
7) Automatic voltage function: system according to the test voltage or manually set of automatic tracking and boost results, stable test voltage, voltage stability can amount to 1.0%.
8) FM range and frequency resolution all can set: FM range set:30~300Hz,45~100Hz,200-300Hz, on-demand setting, can accelerate tuning process; The frequency resolution, according to the needs, presetting 0.1 Hz, efficiency and tuned in tuned balance between accuracy obtained optimization.
9) Frequency adjustment is divided into thick harmonic fine tuning, and automatic resonant point, guarantee for trials in the whole experiment resonant frequency process does not happen drift.
10) Storage measuring datas and print.
20 ~300 Hz Variable Frequency Series Resonance Test Set20 ~300 Hz Variable Frequency Series Resonance Test Set20 ~300 Hz Variable Frequency Series Resonance Test Set20 ~300 Hz Variable Frequency Series Resonance Test Set20 ~300 Hz Variable Frequency Series Resonance Test Set20 ~300 Hz Variable Frequency Series Resonance Test Set

Parameters of Full System
- Rated Capacity: 135kVA;
- Output Voltage: 0-108KV
- Output frequency: 30-300Hz;
- Input Power: 220V/380V ±10 %single phase, 50Hz
- Waveform distortion rate: output voltage distortion ≤ 1%;
- Working time: 30mins under rated load;
Cable testing: continuous 60 minutes under rated load;
- Temperature rise: ≤65K under rated load;
- Working Temperature: -15ºC~+45ºC
- Quality factors:  Q ≥ 50;
                Cable testing Q ≥ 30 (depend on load).
- Stability: Over-current/over-voltage/Flashover protection;Auto Time;Touch Screen;
- Accuracy: RMS 1.5

Application & System configuration
35KV GIS Breakers,Transformer,insulators, busbar AC withstand voltage testing.

 
Configuration

DUT
Reactor
33.75kVA/27kV  4units
Transformer output
35kV/300mm2 Cable(Test voltage:52KV) Length 1000m   2 Reactors in parallel and 2 Reactors in series 3kV
10kV/500mm2 cable
(Test voltage:22KV)
Length 2000m 4 Reactors in parallel 1.5kV
10KVTurbogenerator
(Test voltage:20KV)
50MW 4 Reactors in parallel 1.5KV
10 Generator(Test voltage:20KV) 4500KW 2 Reactors in series 5kV
35KV Power transformer(test voltage:76KV) 20000KVA 4 Reactors in series 5KV
35KV Power system (Test voltage:95KV)
 
GIS,Tranformer,
Insulators..
 4 Reactors in series 5KV
Sr no  Description    Specification Qty
1 Variable frequency power supply
CHXB-7.5KVA/380V/220V
- Rated output capacity: 7.5KW
- Power Supply: 220V/380V ± 15% (single phase), 50Hz
- Output Voltage: 0 - 400V, adjustable;
- Rated Output Current: 0-18.75A;
- Frequency: 30 - 300Hz, 0.1Hz step adjustable
- Frequency resolution:  0.1Hz
- Frequency stability: ≤ 0.02%
1 unit
2 Excitation Transformer
JLB-7.5KVA/1.5KV/5KV/0.2KV/0.4KV

 
- Rated capacity: 7.5KVA;                     
- Input voltage: 400V/200V, single phase;
- Output voltage :1.5kv/3KV/5kV;
- Output current :5A/2.5A/1.5A;
- Frequency:30-300Hz;
1 unit
3 Reactor
DK-33.75KVA/27KV
- Rated Capacity: 33.75kVA;
- Rated voltage: 27kV;
- Rated current: 1.25A;
- Induction:90H/each one
- Continous wroking time: 60mins;
- Temperature rising: <60ºC
- Working frequency: :30-300Hz.
4 units
4 Capacitive Divider
FRC-120KV/1000PF
- Rated voltage: 120KV
- High-voltage capacitance: 1000pF
- Frequency:30-300Hz
1 unit
20 ~300 Hz Variable Frequency Series Resonance Test Set
20 ~300 Hz Variable Frequency Series Resonance Test Set
20 ~300 Hz Variable Frequency Series Resonance Test Set


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier