• AC High Voltage Partial Discharge Hv Resonant Test System Inductive Withstand Voltage Test Set for Transformer, Gis, or Cable
  • AC High Voltage Partial Discharge Hv Resonant Test System Inductive Withstand Voltage Test Set for Transformer, Gis, or Cable
  • AC High Voltage Partial Discharge Hv Resonant Test System Inductive Withstand Voltage Test Set for Transformer, Gis, or Cable
  • AC High Voltage Partial Discharge Hv Resonant Test System Inductive Withstand Voltage Test Set for Transformer, Gis, or Cable
  • AC High Voltage Partial Discharge Hv Resonant Test System Inductive Withstand Voltage Test Set for Transformer, Gis, or Cable
  • AC High Voltage Partial Discharge Hv Resonant Test System Inductive Withstand Voltage Test Set for Transformer, Gis, or Cable

AC High Voltage Partial Discharge Hv Resonant Test System Inductive Withstand Voltage Test Set for Transformer, Gis, or Cable

After-sales Service: Life Time Support
Warranty: 1 Year or Extended
Type: High Voltage Test Equipment
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
AC High Voltage Partial Discharge Hv Resonant Test System Inductive Withstand Voltage Test Set for Transformer, Gis, or Cable pictures & photos
AC High Voltage Partial Discharge Hv Resonant Test System Inductive Withstand Voltage Test Set for Transformer, Gis, or Cable
US $2,000-20,000 / Set
Min. Order: 1 Set
Diamond Member Since 2018

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory

Basic Info.

Model NO.
hmcxz
Accuracy Grade
1.5
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Digital
Control
Computer Control
Weight
500-1000Kg
Power Source
AC380V
Model No.
Hmcxz
Product Name
Inductive Withstand Voltage Test
Output Frequency
30 -300Hz
Waveform
Sine Wave, Thd ≤ 1%
Full Load Working Time
Continuous Working Time 60mins
Output Voltage
800kv (Customsize)
Capacitance
4000kVA(Customsize)
Transport Package
Wooden Box with Foam Inside
Specification
customsize
Trademark
HMDQ
Origin
Hubei, China(Mainland)
HS Code
9031809090
Production Capacity
100sets/Year

Product Description

AC  high voltage partial discharge  inductive withstand voltage test set hv resonant test system for transformer,gis, or cable
 

I. Summary

Partial discharge Indutive Withstand Voltage Test System 
 is suitable for the transfer and preventive test of large-capacity, high-voltage capacitive test products. Taking into account a wide range of applications, the principle of series resonance is used to meet the AC resistance test of high-voltage cables and other capacitor-type samples.

The device is mainly composed of partial discharge variable frequency power source, variable frequency control power supply,partial discharge excitation transformer, partial discharge reactor, partial discharge capacitive voltage divider.



It can test in sections, set the first, second, and third stage test voltage, and carry out section tests,,especially suitable for GIS AC withstand voltage test
 

Product nickname: AC resonant test set, hipot tester, HV resonant test set, AC resonant test system supplier
AC High Voltage Partial Discharge Hv Resonant Test System Inductive Withstand Voltage Test Set for Transformer, Gis, or Cable

 
II. Resonant test system advantage 

 

1. Device with over-voltage,over-current, zero startup, system detuning,high voltage flashover fault,ect  protection function.the over-voltage over-current protection value can be set according to the needs of user.flashover protection movement when the test object flashover, and mark down flashover voltage value, for test analyzed.

2.The whole device ,the largest piece very light weight not more than 40kg and convenient for field use.

3.Device has four working mode, user-friendly according to the site condition flexible choice, improve test speed.working mode as automatic mode,manual mode,automatic tune mode and manual boost mode.

4.Can store and print data,nonlocal print data, the serial number of the stored data is number, easy to help users digital identification and searching.

5.Frequency starting point can be set arbitrarily within prescribed scope when the device automatic frequency sweep.Sweep frequency direction can choose to up or down,, meanwhile color LCD big screen display scanning resonance boost and timing curve, be convenient for the user intuitive understanding whether find resonant point.

6.Adopted DSP platform technology, according to user needs ,can conveniently increase or decrease function and upgrade, but also makes the man-computer exchange interface humanized.
AC High Voltage Partial Discharge Hv Resonant Test System Inductive Withstand Voltage Test Set for Transformer, Gis, or Cable



III.Resonant Test System Parameter
-Rated Capacity: 20-20000kVA;
- Output Voltage: 0-1000KV
- Output Current:0-200A
- Output frequency: 30-300Hz;
- Input Power: 220V/380V ±10 %single phase, 50Hz
- Waveform distortion rate: output voltage distortion ≤ 1%;
- Working time: 30mins under rated load;Cable testing: continuous 60 minutes under rated load;
- Temperature rise: ≤65K under rated load;
- Working Temperature: -15ºC~+45ºC
- Quality factors: Q ≥ 50; Cable testing Q ≥ 30 (depend on load).
- Stability: Over-current/over-voltage/Flashover protection;Auto Time;Touch Screen;
- Accuracy: RMS 1.5 (0.5/1.0/1.5)
- pD Amount:less than 2 pC

Specification can be customzied 
AC High Voltage Partial Discharge Hv Resonant Test System Inductive Withstand Voltage Test Set for Transformer, Gis, or Cable

IV. Resonant Test System application

AC High Voltage Partial Discharge Hv Resonant Test System Inductive Withstand Voltage Test Set for Transformer, Gis, or Cable

AC High Voltage Partial Discharge Hv Resonant Test System Inductive Withstand Voltage Test Set for Transformer, Gis, or Cable


AC High Voltage Partial Discharge Hv Resonant Test System Inductive Withstand Voltage Test Set for Transformer, Gis, or CableAC High Voltage Partial Discharge Hv Resonant Test System Inductive Withstand Voltage Test Set for Transformer, Gis, or CableAC High Voltage Partial Discharge Hv Resonant Test System Inductive Withstand Voltage Test Set for Transformer, Gis, or Cable



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
AC High Voltage Partial Discharge Hv Resonant Test System Inductive Withstand Voltage Test Set for Transformer, Gis, or Cable pictures & photos
AC High Voltage Partial Discharge Hv Resonant Test System Inductive Withstand Voltage Test Set for Transformer, Gis, or Cable
US $2,000-20,000 / Set
Min. Order: 1 Set
Diamond Member Since 2018

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Registered Capital
30000000 RMB
Plant Area
10000 square meters