10A Grounding Lines Group Resistance Tester

Product Details
Customization: Available
Type: Strength Testing Machine
Weight: 18kg
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
30000000 RMB
Plant Area
10000 square meters
  • 10A Grounding Lines Group Resistance Tester
  • 10A Grounding Lines Group Resistance Tester
  • 10A Grounding Lines Group Resistance Tester
  • 10A Grounding Lines Group Resistance Tester
  • 10A Grounding Lines Group Resistance Tester
  • 10A Grounding Lines Group Resistance Tester
Find Similar Products

Basic Info.

Model NO.
HM3001
Power Source
AC180 to 270V, 50/60Hz
Maximum Output Voltage
450V
Output Current
1, 2, 3, 4, 5A
Test Current Waveform
Sine Wave
Transport Package
Wooden Box with Foam Inside
Specification
355 * 335 * 340mm
Trademark
GDHM
Origin
Hubei, China(Mainland)
Production Capacity
500 Sets Per Year

Product Description

10A Grounding Lines Group Resistance Tester
Summary
At present, in the power system, the grounding resistance test of large grounding grids is mainly measured by high frequency current three pole method. In order to prevent the power frequency interference and improve the accuracy of the measurement results, the insulation preventive test regulation stipulates that the test current of the high frequency current method shall not be less than 30 amperes. As a result, there are many problems such as heavy test equipment, complicated test process, great work intensity of test personnel and long test time.

HM3001  Grounding Grid Earth Resistance Tester, test of substation grounding grid (4), fire power plant, microwave station (10), the lightning rod (10) with multiple models, using a new type of variable frequency AC power supply, and adopts the microcomputer control and signal processing and other measures, is a very good solution anti interference problem in the process of testing, simplifies the test operation process, improves the precision and accuracy of the test results, and greatly reduce the labor intensity and the cost of test and test personnel.

The instrument is suitable for testing the power frequency characteristic parameters of various grounding devices, such as power frequency grounding resistance, and the soil resistivity. The instrument adopts different frequency anti-jamming technology, can under the condition of strong interference and accurate measured data under the frequency of 50Hz. The maximum test current is 5A, the potential of the grounding device is not too high when tested, and it also has strong anti-interference ability, so it can be measured under the condition of no power failure.
10A Grounding Lines Group Resistance Tester

Advantage
1.Good power frequency equivalence, test current waveform is sine wave, it has only 5Hz with the power frequency difference, using 45Hz and 55Hz two kinds of frequency to carry on the measurement.
2.Strong anti-interference ability. The instrument adopts the different frequency measurement method, combined with modern hardware and software filtering technology, the instrument has high anti-interference performance, stable and reliable test data.
3.High accuracy, basic error is only 0.005 ohms, which can be used to measure large ground grids with little grounding impedance.
4.Powerful funcation. It can measure the current pile, the grounding resistance of the voltage pile, the grounding resistance of the grounding network, the on resistance, and the soil resistivity.
5. Simple operation. All Chinese/english menu type operation, directly display measurement results.
6.Simple wiring,strong current line is unnecessary.


Technical index
1. Impedance measurement range: 0~5000Ω
2. Resolution: 0.001MΩ
3. Measurement error: + (readings x2%+0.005Ω)
4. Test current waveform: sine wave
5. Test current frequency: 45, 50, 55, 60, 65Hz single frequency
45/55Hz, 55/65Hz, 47.5/52.5Hz automatic dual frequency conversion
6. Output current: 1, 2, 3, 4, 5A
7. Maximum output voltage: 450V
8. Measuring line requirements: current line copper core cross-sectional area  1.5mm2
Voltage line copper core cross-sectional area 1.0mm2
9. Power supply: AC180 to 270V, 50/60Hz
10. Size: 355 * 335 * 340mm
11. Weight: 18kg
10A Grounding Lines Group Resistance Tester


10A Grounding Lines Group Resistance Tester
10A Grounding Lines Group Resistance Tester

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier