Hubei, China
Business Type:
Manufacturer/Factory & Trading Company
Number of Employees:
29
Year of Establishment:
2008-01-28
Management System Certification:
ISO9001:2015, ISO14001:2015, OHSAS18001:2007
Average Lead Time:
Peak season lead time: within 15 workdays
Off season lead time: within 15 workdays
OEM/ODM Service
Sample Available

Hipot Testing Transoformer, AC DC Hipot Tester, Power Testing Transformer manufacturer / supplier in China, offering AC DC High Tension Hipot/3 Phase Hipot Testing Transformer, China Supplier Contact Resistance Test Set for Circuit Breaker, Switchgear., 200A Loop Contact Resistance Tester and so on.

Diamond Member Since 2018
Audited Supplier
  • AC DC High Tension Hipot/3 Phase Hipot Testing Transformer
  • AC DC High Tension Hipot/3 Phase Hipot Testing Transformer

AC DC High Tension Hipot/3 Phase Hipot Testing Transformer

Min. Order / Reference FOB Price
1 Set US $700-16,100/ Set
Port: Wuhan, China
Production Capacity: 500sets/Month
Payment Terms: L/C, T/T, Western Union, Paypal
Type: Strength Testing Machine
Weight: 40
Power Source: AC220V
Input Voltage: AC 220V (10kVA or Below)
No-Load Current: <10%
Impedance Voltage: <10%

You Might Also Like

Loading...

Basic Info.

Model NO.
HM-YDJZ
Ratio Error
<1%
Meter Voltage
100V
Oil Insulation
2.5mm >50kv
Product Name
Hipot Testing Transformer
Trademark
GDHM
Transport Package
Wooden Box with Foam Inside
Specification
320*240*620 mm
Origin
Hubei, China(Mainland)
AC DC High tension Hipot/3 Phase  hipot Testing Transformer

Summary
Oil-immersed Test Transformer are widely used for testing AC/DCwithstand voltage such as electrical equipment, electrical components, insulation materials. This series of test transformer has the advantages of small size, light weight, compact structure, strong universality etc.

Advantage
1.HV bushing was first time made
2.Between the bushing and the oil tank is completely isolated, and all connection parts adopted
 imported "O" type sealing ring seal, so we completely solve the common problems of
 transformer leakage.
3.Sleeping core type design, effectively improve seismic resistance.
4.Before delivery, 24 hours upside down testing and no leakage.
5.All products're passed through 1.1 times induction withstand voltage testing.
6.Pure famous oil-immersed insulating medium.
7. HV & LV cables are made by high strength polyester, oxygen free copper enameled wires.
8.The core was adopted with new WISCO,two silicon cold rolled silicon steel strip

AC DC High Tension Hipot/3 Phase Hipot Testing Transformer

AC DC High tension Hipot/ 3 Phase hipot Testing Transformer

Technical data
1.Input voltage: AC 220V (10KVA or below); AC 400V ( over 10KVA)
2.No-load current:<10%
3.Impedance voltage:<10%
4.Ratio Error: <1%
5.Meter voltage: 100V
6.Oil insulation: 2.5mm >50kV

AC DC High Tension Hipot/3 Phase Hipot Testing Transformer


More type for choice :

AC DC High Tension Hipot/3 Phase Hipot Testing Transformer


AC DC High Tension Hipot/3 Phase Hipot Testing Transformer
AC DC High Tension Hipot/3 Phase Hipot Testing Transformer
AC DC High Tension Hipot/3 Phase Hipot Testing Transformer







 

Send your message to this supplier

*From:
*To:
avatar Ms. Goldhome
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now