Gis Pd Fault Partial Discharge Failure Simulation Test Set

Product Specifications Select Now
160KV
160KV
Product Details
Customization: Available
After-sales Service: Life Long Support
Warranty: 1 Year
Shipping
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Guarantee
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

Industry-leading Audited Factory

Secured Trading Service
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Fast Delivery
The supplier can deliver the goods within %s days
Management Certification
The supplier has quality management system certification, including: %s
Product Certification
The supplier's products already have relevant certification qualifications, including: %s
to see all verified strength labels (28)
  • Gis Pd Fault Partial Discharge Failure Simulation Test Set
  • Gis Pd Fault Partial Discharge Failure Simulation Test Set
  • Gis Pd Fault Partial Discharge Failure Simulation Test Set
  • Gis Pd Fault Partial Discharge Failure Simulation Test Set
  • Gis Pd Fault Partial Discharge Failure Simulation Test Set
  • Gis Pd Fault Partial Discharge Failure Simulation Test Set
Find Similar Products

Basic Info.

Model NO.
HM160
Type
Gis Test Equipment
Power Source
AC220V
Output Voltage
110~500kv
Pd Under Rated Volt(PC)(250-600)
<1PC
Adjustment Method
Manual, Electric
Coupling Capacitance
50PF
Product Name
Gis Test Equipment
Certificate
Factory Caliration Test Report
Standard
GB and IEC
Applicated
Gis Test at Site or Lab
Transport Package
Wooden Box with Foam Inside
Trademark
HMDQ
Origin
Hubei, China(Mainland)
HS Code
9030390000
Production Capacity
100sets/ Year

Packaging & Delivery

Package Size
2210.00cm * 850.00cm * 2150.00cm
Package Gross Weight
600.000kg

Product Description

GIS  PD  Fault  Partial Discharge Failure Simulation test set 

I. Brief introduction

 GIS defects simulation device simulate various discharge phenomena inside GIS, suitable for experimental research and instrument assessment of GIS partial discharge live detection.

Gis Pd Fault Partial Discharge Failure Simulation Test Set
 
II. Features
1. Good authenticity: It is designed according to the physical GIS, and the various partial discharge faults inside the GIS are truly simulated.
 
2. Good integrity: high-voltage equipment such as step-up transformers and coupling capacitors are built into the GIS.
 
3. Fault simulation: It can simulate GIS tip, suspension, air gap, particle, creeping and other discharge types, and multiple discharges can be combined.


 Gis Pd Fault Partial Discharge Failure Simulation Test Set
4. Controllable discharge: The type of discharge can be selected arbitrarily to control the initial voltage, extinguishing voltage and discharge intensity of each discharge signal.
 
5. Diversified detection: It can provide a test platform for pulse current, UHF, ultrasonic, high frequency, SF6 gas analysis and other technical detection.
 
6. Metering transmission: Built-in pulse current method related coupling and calibration unit, which can be detected simultaneously.
 
7. Good stability: Each discharge module can be used repeatedly, and the discharge characteristics are stable.
 
8. Convenient operation: the occurrence and disappearance of various faults can be directly controlled outside the device.
 
9. Diversification of basins: The basin insulators are equipped with various types such as fully shielded, bare basin, and pouring port.
 
10. Visualization: Built-in infrared video probe, convenient to observe the internal state and capture discharge video.
 
11. Built-in sensor: built-in ultra-high frequency sensor, which is convenient for comparison with the tested instrument.
Gis Pd Fault Partial Discharge Failure Simulation Test Set

 
III. Parameter
1.Voltage level: 110~500kV
2.Partial discharge: ≤1pC
3.Adjustment method: manual, electric
4.Coupling capacitance: 50pF
5.Discharge simulation: tip 5~800pC, particle 0.1~10pC, suspension 100~20000pC, air gap 10~1000pC, along the surface 10~1000pC
Gis Pd Fault Partial Discharge Failure Simulation Test Set

Gis Pd Fault Partial Discharge Failure Simulation Test SetGis Pd Fault Partial Discharge Failure Simulation Test Set




Gis Pd Fault Partial Discharge Failure Simulation Test SetGis Pd Fault Partial Discharge Failure Simulation Test SetGis Pd Fault Partial Discharge Failure Simulation Test SetGis Pd Fault Partial Discharge Failure Simulation Test SetGis Pd Fault Partial Discharge Failure Simulation Test Set







 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Send Inquiry
Chat Now