• Resonance Circuit Test Set for Gis / CT PT Testing /High Voltage Cable Resonance Withstand Test System
  • Resonance Circuit Test Set for Gis / CT PT Testing /High Voltage Cable Resonance Withstand Test System
  • Resonance Circuit Test Set for Gis / CT PT Testing /High Voltage Cable Resonance Withstand Test System
  • Resonance Circuit Test Set for Gis / CT PT Testing /High Voltage Cable Resonance Withstand Test System
  • Resonance Circuit Test Set for Gis / CT PT Testing /High Voltage Cable Resonance Withstand Test System

Resonance Circuit Test Set for Gis / CT PT Testing /High Voltage Cable Resonance Withstand Test System

Type: Universal Testing Machine
Accuracy Grade: 1.5
Display: LCD
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Resonance Circuit Test Set for Gis / CT PT Testing /High Voltage Cable Resonance Withstand Test System pictures & photos
Resonance Circuit Test Set for Gis / CT PT Testing /High Voltage Cable Resonance Withstand Test System
US $2,000-20,000 / Set
Min. Order: 1 Set
Diamond Member Since 2018

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory

Basic Info.

Model NO.
HMCXZ 108kVA 108KV
Power Source
220V/380V
Ra Ted Output Capacity
6kw
Transport Package
Wooden Box with Foam Inside
Trademark
GDHM
Origin
Hubei, China(Mainland)
Production Capacity
500sets/Month

Product Description

Advantage
1) Placed way: the placement of variable frequency power for longitudinal and transverse, especially suitable for field operation and observe.
2) Shockproof protection: internal and external have special damping rubber support foot and protect aluminum boxes, which can effectively slow motion and lifting the bumpy transport the shock. Ensure the inverter power long-term stability and reliability.
3) Parameter display: touch or external mouse LCD interface display system.
Can show resonance voltage (namely test before setting goals voltage), test frequency, measure frequency, low-pressure voltage, low voltage electric current, voltage time, over-voltage protection, over-current protection, flash winding protection, phase booster and stage timing, operation mode switch, capacitor, inductance, frequency swap calculation, parameters, still can show inquiry on frequency curve, voltage curve can intuitivey judgment when trials resonance frequency accurately and stability.
4) Parameter Settings: big screen touch LCD backlit and external mouse directly in completing various parameters Settings. But on the initial frequency, termination frequency, starting voltage, phase booster and timing, measuring bleeder variable ratio, incentive change ratio, over-voltage protection, over-current protection, flash winding protection, test mode, capacitance inductance frequency swap calculation, parameter setting tips, and help parameters Settings or choice.
5) Test mode: touch screen and external mouse operation, there is automatic and semi-automatic, manual three operating status. With pressor, tuning (including manual, automatic), subsection pressurized and timing, running status, pattern switching, troubleshooting tips, capacitance inductance frequency swap computing functions, etc.
6) Protection function and information clew: having high-pressure over-voltage protection, low-pressure over-current, over-current protection, as well as detuning protection, zero, shem winding protection, emergency stop, undervoltage protection multiple protection function.
7) Automatic voltage function: system according to the test voltage or manually set of automatic tracking and boost results, stable test voltage, voltage stability can amount to 1.0%.
8) FM range and frequency resolution all can set: FM range set:30~300Hz,45~100Hz,200-300Hz, on-demand setting, can accelerate tuning process; The frequency resolution, according to the needs, presetting 0.1 Hz, efficiency and tuned in tuned balance between accuracy obtained optimization.
9) Frequency adjustment is divided into thick harmonic fine tuning, and automatic resonant point, guarantee for trials in the whole experiment resonant frequency process does not happen drift.
10) Storage measuring datas and print.
10kV/35KV Power transformers, GIS Breakers,Transformer,insulators, busbar AC withstand voltage testing.



Parameters of Full System
- Rated Capacity: 108kVA;
- Output Voltage: 0-108KV
- Output frequency: 30-300Hz;
- Input Power: 220V/380V ±10 %single phase, 50Hz
- Waveform distortion rate: output voltage distortion ≤ 1%;
- Working time: 30mins under rated load;
Cable testing: continuous 60 minutes under rated load;
- Temperature rise: ≤65K under rated load;
- Working Temperature: -15ºC~+45ºC
- Quality factors:  Q ≥ 50;
                Cable testing Q ≥ 30 (depend on load).
- Stability: Over-current/over-voltage/Flashover protection;Auto Time;Touch Screen;
- Accuracy: RMS 1.5
Resonance Circuit Test Set for Gis / CT PT Testing /High Voltage Cable Resonance Withstand Test System
Resonance Circuit Test Set for Gis / CT PT Testing /High Voltage Cable Resonance Withstand Test System

Application & System configuration

10kV/35KV Power transformers, GIS Breakers,Transformer,insulators, busbar AC withstand voltage testing.

 
Configuration

DUT
Reactor
27kVA/27kV  4units
Transformer output
35kV/240mm2 Cable(Test voltage:52KV) Length 1000m   2 Reactors in parallel and 2 Reactors in series 3kV
10kV/300mm2 calbe
(Test voltage:24KV)
Length 2000m 4 Reactors in parallel 1.5kV
10.5KV/20KV Generator(Test voltage:24KV) 60/130KW 4 Reactors in parallel 1.5kV
10kV/35KV Power transformer (Test voltage:44/95KV)
 
GIS,Tranformer,
Insulators..
 2 Reactors or 4 Reactors in series 5KV
Sr no  Description    Specification Qty
1 Variable frequency power supply
CHXB-6KV/380V/220V
- Rated output capacity: 6KW
- Power Supply: 220V/380V ± 15% (single phase), 50Hz
- Output Voltage: 0 - 400V, adjustable;
- Rated Output Current: 0-15A;
- Frequency: 30 - 300Hz, 0.1Hz step adjustable
- Frequency resolution:  0.1Hz
- Frequency stability: ≤ 0.02%
1 unit
2 Excitation Transformer
JLB-6KVA/1.5KV/5KV/0.2KV/0.4KV

 
- Rated capacity: 6KVA;                     
- Input voltage: 400V/200V, single phase;
- Output voltage :1.5kv/3KV/5kV;
- Output current :4A/2A/1.2A;
- Frequency:30-300Hz;
1 unit
3 Reactor
DK-27KVA/27KV
- Rated Capacity: 27kVA;
- Rated voltage: 27kV;
- Rated current: 1A;
- Induction:110H/each one
- Continous wroking time: 60mins;
- Temperature rising: <60ºC
- Working frequency: :30-300Hz.
4 units
4 Capacitive Divider
FRC-120KV/1000PF
- Rated voltage: 120KV
- High-voltage capacitance: 1000pF
- Frequency:30-300Hz
1 unit

Resonance Circuit Test Set for Gis / CT PT Testing /High Voltage Cable Resonance Withstand Test System
Resonance Circuit Test Set for Gis / CT PT Testing /High Voltage Cable Resonance Withstand Test System
Resonance Circuit Test Set for Gis / CT PT Testing /High Voltage Cable Resonance Withstand Test System

 

Send your message to this supplier

*From:
*To:
avatar Ms. Goldhome
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Resonance Circuit Test Set for Gis / CT PT Testing /High Voltage Cable Resonance Withstand Test System pictures & photos
Resonance Circuit Test Set for Gis / CT PT Testing /High Voltage Cable Resonance Withstand Test System
US $2,000-20,000 / Set
Min. Order: 1 Set
Diamond Member Since 2018

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Registered Capital
30000000 RMB
Plant Area
10000 square meters