300kv DC High Voltage Generator for Cable Test

Product Details
Customization: Available
After-sales Service: Life Long Support
Warranty: 1 Year or Extended

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
30000000 RMB
Plant Area
10000 square meters
  • 300kv DC High Voltage Generator for Cable Test
  • 300kv DC High Voltage Generator for Cable Test
  • 300kv DC High Voltage Generator for Cable Test
  • 300kv DC High Voltage Generator for Cable Test
  • 300kv DC High Voltage Generator for Cable Test
  • 300kv DC High Voltage Generator for Cable Test
Find Similar Products

Basic Info.

Model NO.
HMZGF
Display
Digital
Control
Manual Control
Power Source
AC220V
Usage
DC High Voltage Tester
Output Type
DC
Output Voltage
60-300kv
Output Current
2\3\5\10mA
Over Voltage Rectify Accuracy
<=1.0%
Ripple Factor
<=0.5%
Altitude
Below 2500m
Product Name
DC Hipot Tester
Ripple
≤0.5%
Voltage Precision
1% ±1 Word
Certificate
ISO, SGS
Standard
IEC
Work Power
AC 220V±10%;50Hz
0.75 Switch Over Accuracy
≤0.5%
Test Sample
Cable, Arrester, Transformer
Transport Package
Plywood Box with Foam Inside
Specification
customize
Trademark
HMDQ
Origin
Hubei, China(Mainland)
HS Code
9030339000
Production Capacity
500sets/Month

Product Description

300KV DC high voltage generator for cable test

I. Summary
Newly researched, designed, and manufactured according to "Common technical condition for portable DC HV generator" of China Industry Standard, the HMZGF series DC hipot tester is a technology product of new era, suitable for DC HV test on zincoxidearrester, magnetic blow-out arrester, power cable, generator, transformer, and switch in electric power department, scientific research unit, railway station, power plant, chemical plant, etc., a optimal upgrading product in new era.

300kv DC High Voltage Generator for Cable Test


II. Application

1) MOA lightning-arrester HVDC hi-pot
2) HVDC hi-pot and leak current measurement for HV electrical equipment, such as transformer, switchgear, and oil-type power cable
3) Leak current measurement for water-cooling DC power generators
4) High-stability DC HV generators with high-precision DC voltage-divider for DC HV standardization

III.Main Feature
1.dc high voltage generator(dc high voltage tester) is portable at site,light in weight & small size
2.With AIPWM technology, avoid the inaccuracy linearity of PWM ,High precision, exact measure,and Ripple factor ≤0.5 %
3.AI Zinc Oxide arrester and oil-immersed transformer measure function ,test report can be saved directly,accuracy ≤0.5 %, 75% UDC 1mA function button.
4.with AI technology to set over-voltage protection and over-current protection instead of digital dial switch which can only set voltage value,Error ≤1% .
5.Full range of smooth voltage regulation, voltage regulation precision ≤1%, stability ≤1%, voltage and current error ≤ 1.0%±1
6.With the total time T1 and segment timing T2, and arbitrary voltage, current timing function
7.dc high voltage generator(dc high voltage tester) adds a calendar and time function



IV. Detailed Images of DC hipot tester

300kv DC High Voltage Generator for Cable Test



V.Technical parameters of DC hipot tester
  Specification

Technical
Parameter
60/5 120/5 100/10 160/2 180/2 200/2 250/2 100/200
3/2
200/300
3/2
Others
Output voltage
(kV)
60 120 100 160 180 200 250 100/200 200/300

600~800kV
Produce according to the contract
Output current (mA) 5 5 10 2 2 2 2 3/2 3/2
Output power (W) 300 600 1000 320 360 400 500 400 600
Charging current
(mA)
5.0 5.0 12.0 3.0 3.0 3.0 3.0 4.5/3.0 4.5/3.0
Case weight (kg) 4.5 7 5.3 4.3 4.3 4.4 4.5 4.5 8.1
Dimension of multivoltage tube (mm) Φ80
×500
Φ80
×770
Φ80
×770
Φ80
×770
Φ110
×770
Φ110
×770
Φ110
×820
Φ110
×800
Φ110
×1350
Height of multivoltage tube (kg) 7.3 9 7.5 7.2 7.2 7.2 7.6 7.5 12.6
HV polarity Polarity of negative volt, zero voltage start, continuous adjustable
Work power AC 220V±10%;50Hz
Voltage measuring accuracy 1.0%(full scale)±1character, max resolution 0.1%kV
Current measuring accuracy 1.0%(full scale)±1character, max resolution 0.1%uA
Over voltage rectify accuracy ≤1.0%
0.75 switch over accuracy ≤0.5%
Ripple factor ≤1.0%
Voltage stability Random fluctuation, when voltage change of power supply±10% ≤0.5%
Work manner Intermittent service; 30min of rated load;1.1 times of rated voltage use:10min
Temperature -15ºC~50ºC
Relative humidity When at 25ºC,no more than 90%(no condensation)
Altitude Below 2500m

More specifications can be customized .

VI. Electric functional diagram
300kv DC High Voltage Generator for Cable Test
300kv DC High Voltage Generator for Cable Test
300kv DC High Voltage Generator for Cable Test300kv DC High Voltage Generator for Cable Test

VII. Related  Product

 

300kv DC High Voltage Generator for Cable Test
300kv DC High Voltage Generator for Cable Test
300kv DC High Voltage Generator for Cable Test

 

300kv DC High Voltage Generator for Cable Test300kv DC High Voltage Generator for Cable Test300kv DC High Voltage Generator for Cable Test300kv DC High Voltage Generator for Cable Test300kv DC High Voltage Generator for Cable Test300kv DC High Voltage Generator for Cable Test300kv DC High Voltage Generator for Cable Test









 

Send your message to this supplier