Transformer Sweep Frequency Response Analysis Sfra Tester for Transformer Test

Product Details
Customization: Available
After-sales Service: Suppor for Lifelong
Warranty: 1 Year or Extend

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
30000000 RMB
Plant Area
10000 square meters
  • Transformer Sweep Frequency Response Analysis Sfra Tester for Transformer Test
  • Transformer Sweep Frequency Response Analysis Sfra Tester for Transformer Test
  • Transformer Sweep Frequency Response Analysis Sfra Tester for Transformer Test
  • Transformer Sweep Frequency Response Analysis Sfra Tester for Transformer Test
  • Transformer Sweep Frequency Response Analysis Sfra Tester for Transformer Test
  • Transformer Sweep Frequency Response Analysis Sfra Tester for Transformer Test
Find Similar Products

Basic Info.

Model NO.
HM5010
Type
Transformer Tester
Display
Digital
Control
Computer Control
Power Source
AC220V
Test Range
(-100dB) - (+20dB)
Frequency Accuracy
<0.01%
Scan Mode 1
Linear Scanning Distribution
Scan Mode 2
Segment Frequency Scanning Measurement Distributio
Frequency Scanning Measurement Range
(0.5kHz) - (1MHz)
Scanning Frequency Accuracy
0.01%
Amplitude Measurement Accuracy
0.1dB
Amplitude Measurement Range
(-120dB) to (+20 dB)
Ignal Input Impedance
1mΩ
Ignal Output Impedance
50Ω
Nw
13kgs
Standard
IEC
Certificate
ISO, SGS, TUV
Transport Package
Wooden Box with Foam Inside
Specification
31cm *15cm *15cm
Trademark
HMDQ
Origin
Hubei, China(Mainland)
Production Capacity
500 Set Per Year

Product Description

Sweep Frequency Response Analysis (Sfra) Tester for transformer 

I. Overview
The Sweep Frequency Response Analyzer is used for power transformer with voltage grade of 66kV and above and other transformers with special purpose. The power transformer is inevitably vulnerable to impulse of various fault short-circuit current or physical collision in the process of operation and transportation and the transformer windings may lose stability under the powerful electro-dynamic force exerted by such short-circuit current, which could result in permanent deformations such as local distortion, swell or dislocation and will severely affect safe operation of the transformer.


Transformer Sweep Frequency Response Analysis Sfra Tester for Transformer Test
II. Main Technical Characteristics
  1. Characteristics of transformer windings are measured with frequency sweep method. Deformations of windings such as distortion, swell or displacement of 66kV and above transformer are measured by detecting amplitude-frequency response characteristics of each winding, not requiring lifting of transformer enclosure or disintegration.
  2. Quick measuring, measuring of a single winding is within 2 minutes.
  3. High frequency accuracy, higher than 0.001%.
  4. Digital frequency synthesis, with higher frequency stability.
  5. 5000V voltage isolation fully protects safety of the testing computer.
  6. Able to load 9 curves at the same time and automatically calculate parameters of each curve and diagnose winding deformations to provide the reference diagnosis conclusion.
  7. Analysis software has powerful functions and software and hardware indicators satisfy national standard DL/T911-2016/IEC60076-18.
  8. Software management is humanized with high degree of intelligence. You only need to click one key to complete all measurements after setting of parameters.
  9. The software interface is concise and vivid, with clear menus of analysis, save, report export, print, etc.

III. Main technical parameters
  1. Measuring speed: 1 min- 2 min for single-phase winding
  2. Output voltage: Vpp-25V, adjusting automatically in test
  3. Output impedance: 50Ω
  4. Input impedance: 1MΩ (the response channel is built with 50Ω matching resistance)
  5. Frequency sweep scope: 10Hz-2MHz  
  6. Frequency accuracy: 0.001%
  7. Frequency sweep manner: linear or logarithmic, frequency sweep interval and number of sweep points are freely settable
  8. Curve display: amplitude-frequency curve
  9. Width of measuring dynamic range: -100dB~20dB
  10. Supply voltage: AC100-240V   50/60Hz  (use DC12V Adapater recommend)


Transformer Sweep Frequency Response Analysis Sfra Tester for Transformer Test

Transformer Sweep Frequency Response Analysis Sfra Tester for Transformer TestTransformer Sweep Frequency Response Analysis Sfra Tester for Transformer TestTransformer Sweep Frequency Response Analysis Sfra Tester for Transformer TestTransformer Sweep Frequency Response Analysis Sfra Tester for Transformer TestTransformer Sweep Frequency Response Analysis Sfra Tester for Transformer TestTransformer Sweep Frequency Response Analysis Sfra Tester for Transformer Test



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier