Segment Frequency Scanning Measurement Distributio
Frequency Scanning Measurement Range
(0.5kHz) - (1MHz)
Scanning Frequency Accuracy
0.01%
Amplitude Measurement Accuracy
0.1dB
Amplitude Measurement Range
(-120dB) to (+20 dB)
Ignal Input Impedance
1mΩ
Ignal Output Impedance
50Ω
Nw
13kgs
Standard
IEC
Certificate
ISO, SGS, TUV
Transport Package
Wooden Box with Foam Inside
Specification
31cm *15cm *15cm
Trademark
HMDQ
Origin
Hubei, China(Mainland)
Production Capacity
500 Set Per Year
Product Description
Sweep Frequency Response Analysis (Sfra) Tester for transformer
I. Overview The Sweep Frequency Response Analyzer is used for power transformer with voltage grade of 66kV and above and other transformers with special purpose. The power transformer is inevitably vulnerable to impulse of various fault short-circuit current or physical collision in the process of operation and transportation and the transformer windings may lose stability under the powerful electro-dynamic force exerted by such short-circuit current, which could result in permanent deformations such as local distortion, swell or dislocation and will severely affect safe operation of the transformer.
II. Main Technical Characteristics
Characteristics of transformer windings are measured with frequency sweep method. Deformations of windings such as distortion, swell or displacement of 66kV and above transformer are measured by detecting amplitude-frequency response characteristics of each winding, not requiring lifting of transformer enclosure or disintegration.
Quick measuring, measuring of a single winding is within 2 minutes.
High frequency accuracy, higher than 0.001%.
Digital frequency synthesis, with higher frequency stability.
5000V voltage isolation fully protects safety of the testing computer.
Able to load 9 curves at the same time and automatically calculate parameters of each curve and diagnose winding deformations to provide the reference diagnosis conclusion.
Analysis software has powerful functions and software and hardware indicators satisfy national standard DL/T911-2016/IEC60076-18.
Software management is humanized with high degree of intelligence. You only need to click one key to complete all measurements after setting of parameters.
The software interface is concise and vivid, with clear menus of analysis, save, report export, print, etc.
III. Main technical parameters
Measuring speed: 1 min- 2 min for single-phase winding
Output voltage: Vpp-25V, adjusting automatically in test
Output impedance: 50Ω
Input impedance: 1MΩ (the response channel is built with 50Ω matching resistance)
Frequency sweep scope: 10Hz-2MHz
Frequency accuracy: 0.001%
Frequency sweep manner: linear or logarithmic, frequency sweep interval and number of sweep points are freely settable