Hv Supply for Partial Discharge Test System/Pd-Free Detector with Small Pd Value
Product Details
| Customization: | Available |
|---|---|
| Type: | Universal Testing Machine |
| Frequency: | 50Hz |
Secured Trading Service
Diamond Member Since 2018
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Importers and Exporters
Fast Delivery
Management Certification
Product Certification
The supplier has import and export rights
The supplier can deliver the goods within 15 days
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
The supplier's products already have relevant certification qualifications, including:
CE
CE
Sign In to see all verified strength labels (28)
Find Similar Products
Basic Info.
- Model NO.
- HM-YDQW
- Phase
- Single Phase
- Partial Discharge
- 1-3PC
- Output Voltage
- 0-280kv
- Dielectric Loss
- <0.3%
- Rated Capacity
- 150kVA
- Output Voltage(Customized)
- AC 0-1000kv
- Rated Capacity(Customized)
- 5-1000kVA
- Transport Package
- Wooden Box with Foam Inside
- Specification
- 800 (L) * 710 (W) * 1380mm (H)
- Trademark
- HMDQ
- Origin
- Hubei, China(Mainland)
- HS Code
- 9030339000
- Production Capacity
- 50sets/Month
Product Description
HV supply for Partial Discharge Test System /hipot tester
HV euqipment for Partial Discharge Test System /hipot tester is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer, mutual inductor and lightning arresters. It widely used in electrical manufacturing, power operation departments, research institutes and universities.
HM-YDQW 150kVA/280kV HV supply for Partial Discharge Test System Composition.
1.Testing transformer
2.Voltage Divider (concurrently as coupling capacitor)
3.Current Limiting Resistors
4.Power Isolation Filter
5.Console
6.Limb voltage regulator ( built-in Console)
Function Of The Console
The Console is equipped with over-current protection function, upper and lower voltage function, voltage withstand time recording, protection function, emergency button, alarm bell and door linkage.
The Console is equipped with capacitance voltage divider measuring voltmeter (digital
three-and-a-half), transformer primary winding ammeter and voltmeter.
The Console is equipped with upper and lower voltage regulator protection.
Power of Console is single phase power ;Running time: same as Testing Transformer.
HV supply for Partial Discharge Test System /Hipot Tester
Remark:Can be customied according to user's needs.

HV supply for Partial Discharge Test System /hipot tester
According to structure , the device can be divided into four type: single phase iron shell type,
single phase iron shell series type, single phase insulating clinger type and single phase insulating clinger series type. Usually single phase iron shell type is suitable for the occasions where voltage capacity is low and easy to carry , or the equipment is fixed and its voltage capacity is high but with low requirement for partial discharge . Single phase insulating clinger type is usually suitable for the occasions where the requirement of partial discharge is high, but low voltage and fixed. Single phase insulating clinger series type is mainly used for the occasions where the requirement of partial discharge is high,and high voltage,large capacity and easy to carry. All above four type can be select by user's requirement.

HV euqipment for Partial Discharge Test System /hipot tester is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer, mutual inductor and lightning arresters. It widely used in electrical manufacturing, power operation departments, research institutes and universities.
HM-YDQW 150kVA/280kV HV supply for Partial Discharge Test System Composition.
1.Testing transformer
2.Voltage Divider (concurrently as coupling capacitor)
3.Current Limiting Resistors
4.Power Isolation Filter
5.Console
6.Limb voltage regulator ( built-in Console)
Function Of The Console
The Console is equipped with over-current protection function, upper and lower voltage function, voltage withstand time recording, protection function, emergency button, alarm bell and door linkage.
The Console is equipped with capacitance voltage divider measuring voltmeter (digital
three-and-a-half), transformer primary winding ammeter and voltmeter.
The Console is equipped with upper and lower voltage regulator protection.
Power of Console is single phase power ;Running time: same as Testing Transformer.
HV supply for Partial Discharge Test System /Hipot Tester
Main Parameter:
| Rated Capacity | 5-1000kVA | Impedance Voltage | 10% |
| Input Voltage | AC 220V/AC 380V | Output Voltage Waveform | Power frequency, sine wave |
| Output Voltage | AC 0-1000kV | Surface Temperature | Oil immersed:<55ºC Gas: <50ºC |
| Partial Discharge | Under rated voltage≤5PC | No-load Loss | 0.2%-0.35% |
| Insulation Mode | Oil, Gas | Allowed Continuous Operation Time | 1min as per |
Remark:Can be customied according to user's needs.

HV supply for Partial Discharge Test System /hipot tester
According to structure , the device can be divided into four type: single phase iron shell type,
single phase iron shell series type, single phase insulating clinger type and single phase insulating clinger series type. Usually single phase iron shell type is suitable for the occasions where voltage capacity is low and easy to carry , or the equipment is fixed and its voltage capacity is high but with low requirement for partial discharge . Single phase insulating clinger type is usually suitable for the occasions where the requirement of partial discharge is high, but low voltage and fixed. Single phase insulating clinger series type is mainly used for the occasions where the requirement of partial discharge is high,and high voltage,large capacity and easy to carry. All above four type can be select by user's requirement.

Send your message to this supplier
People who viewed this also viewed
Find Similar Products By Category
- Supplier Homepage
- Products
- PD free HV Test Set
- Hv Supply for Partial Discharge Test System/Pd-Free Detector with Small Pd Value
Related Categories
Hot Searches
More