Customization: | Available |
---|---|
After-sales Service: | Life Long Support |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
AC DC HV lab Test System for transformer test
AC Hipot testing is the effective and direct way to test insulation strength for electric equipment, apparatus or machines. It checks dangerous flaws which assure electric equipment continuous working. Typical applications include testing of transformers, switchgear, cables, capacitors, aerial motors platforms, hot sticks bucket bricks, vacuum bottles and other related equipment like vacuum interrupters, blankets, ropes, gloves, hydraulics hose, instruments transformers generators.
Our testing transformer covers oil-filled testing transformer, sf6 gas type testng transformer, and dry type testing transformer.
the controller part, we can customize into manual console., automatic console and electric console.
duty time also can customize according to client's requirements.
1.Oil-immersed test transformer is compact, stable and durable, and low in price.
2.The wiring is simple and intuitive, easy to use.
3.Constant temperature vacuum filling process, better performance of the equipment insulation.
4.Good insulation and beautiful appearance.
5.Small volume, light weight, complete function.
6.DC output can be converted according to the requirement.
7.It can also be customized according to user requirements.
Different type for choice as below:
FAQ About The AC/DC high voltage test equipment
1. Q: What is the language? After sale service,the Warranty?
A:English version or as your requirement.Warranty : 1 year.
2. Q: Does it output AC or DC or AC&DC?
A: We have AC and AC&DC, for your choice.
3. 3. Q: Whether does it have battery or liquid ? Convinent to delivery?
A: Some models have insulation oil, no battey, which does not influence the delivery.
4. Q: Where is it used?
A: Testing dielectric strength of High-voltage electrical equipment, electrical components, insulation material. For example,cable, high-tension switch etc.
5. Q: What types of testing equipment?What's the difference?
A: There are dry, oil-immersed and inflatable,three types. Differences as follow:
Dry: light weight, volume light, can rewind.
Inflatable: interrupter resistance, and light weight.
Oil-immersed: capacity, cheap, easy maintenance, mainstream products.
Specification | Capacity | Input | Ouput | Current | DC Output | Weight |
( kVA ) | ( V ) | ( kV ) | ( mA ) | ( kV ) | ( kg ) | |
1.5/50 | 1.5 | 200 or 400 |
50 | 30 | 70 | 15 |
3/50 | 3 | 60 | 20 | |||
5/50 | 5 | 100 | 30 | |||
10/50 | 10 | 200 | 40 | |||
15/50 | 15 | 300 | 50 | |||
20/50 | 20 | 400 | 55 | |||
25/50 | 25 | 500 | 60 | |||
30/50 | 30 | 600 | 65 | |||
5/100 | 5 | 200 or 400 |
100 | 50 | 140 | 60 |
10/100 | 10 | 100 | 65 | |||
15/100 | 15 | 150 | 70 | |||
20/100 | 20 | 200 | 75 | |||
25/100 | 25 | 250 | 80 | |||
15/120 | 15 | 120 | 125 | 85 | ||
20/120 | 20 | 160 | 90 | |||
25/120 | 25 | 200 | 95 | |||
30/120 | 30 | 250 | 100 |