The rapid development of modern industry, the insulation test of high-voltage equipment puts forward higher requirements, and the traditional measurement methods will face severe tests. With the large-scale application practice of optical fiber in intelligent substation, it has good insulation and anti-interference ability, high measurement accuracy, easy miniaturization, and extremely low failure rate, which has received extensive attention. It is widely used to solve the evaluation of electrical insulation quality of large high-voltage transformers, electric motors, generators, long-distance power cables and tubular busbars under high-voltage substation and power plant on-site strong interference.
2. Features.
The optical digital insulation resistance tester is developed using the Faraday effect of magneto-optical crystal, IE660044.7 and IEC61850 to produce an optical digital insulation resistance tester:
1. Optical digital insulation resistance tester will not generate radiation and electromagnetic pulse, strong anti-interference ability and accurate measurement data.
2. Since the light is an insulator, the high voltage can be effectively isolated (to ensure the personal safety of the operator), and the accuracy and reliability of the sampled data are ensured while suppressing noise.
3. Can cope with its harsh test environment.
4.5.7-inch large screen display, actual test voltage display, leakage current display.
5. True automatic discharge function, no need to manually discharge.
6. Short-circuit current 10mA Strong anti-interference ability.
7. High output power of the instrument, real-time voltage measurement (actual charged voltage of the sample), leakage current measurement, automatic discharge (discharge voltage measurement)
8. Intelligent voice prompt function
After starting up, the voice prompts "Welcome to use the anti-interference insulation resistance tester, please select the appropriate voltage for measurement". After starting, the voice prompts "Do not approach the high voltage danger". After the automatic measurement is completed, the voice prompts "Measurement is over, it is discharging automatically, then the discharge is completed, and the discharge voltage is 0v.
1).Designed in strict accordance with safety standards, output voltage: 500v 1000v, 2500v, 5000v, 10000v.
2).This instrument automatically calibrates the function and automatically calibrates the accuracy before testing.
3).This instrument has the actual test product charging voltage measurement function, leakage current measurement function, automatic discharge function. It can be visually seen through the actual test product charging voltage measurement function whether the drop voltage of the test instrument after the load meets the national requirements. Moreover, the actual test sample charging voltage measurement function and leakage current measurement function can visually see the quality of the sample insulation.
4).It can automatically measure and memorize R15S, R60S and R10min values, and automatically display the polarization index (PI), the induced absorption ratio (DAR) test value and test time.
5).Excellent anti-interference performance. When the interference current reaches 600mA, the instrument still guarantees test accuracy and strong anti-interference ability. It is especially used in 110KV and above large-capacity transformers and long-distance power cable power systems.
6).Automatic discharge: The advanced high-voltage discharge technology is used to quickly discharge the capacitive sample. The discharge voltage is measured in real time during discharge (test sample voltage is 0v). For example, the test sample voltage is 10000v, then the discharge is stopped by 10000v when the test is stopped. Go to 0v (real-time visual display) to monitor the discharge voltage in real time, and prompt "safe disconnection", the operator can disconnect the line (for the extra large test sample, after the automatic discharge, please perform manual discharge to remove the line!) .
7).Internal rechargeable lithium battery power supply or AC power supply, the real AC and DC does not affect the test accuracy.
8).The analog pointer and the digital display coexist. The digital value reflects the accuracy of the insulation resistance of the test object. The analog pointer can reflect the dynamic change of the insulation resistance during the test.
9).The alarm function during boosting, the buzzer warning has high voltage output, away from the sample, and the warning sound stops automatically after the test.
10).Battery power digital display and undervoltage alarm protection.
11).Intelligent battery charging management can effectively prevent battery overcharging.
12).Automatic shutdown function: The instrument has an automatic shutdown function, and the measurement is completed for 5 minutes and automatically shuts down.
13).Short circuit protection, the instrument will not be burnt out in the short circuit condition (use the voltage level within 2500V as much as possible in the nuclear phase).
Rated voltage(kV) | 0.25,0.5,1,2.5,5 | 0.5,1,2.5,5,10 | |
Measurement voltage(kV) | Rated voltage×(1±10%), The load resistance is not less than 1% of the test range | ||
Minimum error is 5% RDG range |
(0.001~100)GW/5kV (0.001~200)GW/2.5kV (0.001~50)GW/1kV (0.001~20)GW/0.5kV (0.001~5)GW/0.25kV |
(0.001~100)GW/10kV (0.001~200)GW/5kV (0.001~200)GW/2.5kV (0.001~100)GW/1kV (0.001~20)GW/0.5kV |
|
Maximum error is 10 % RDG range |
(100~200)GW/5kV (5~10)GW/0.25kV |
(100~200)GW/10kV (100~200)GW/5kV |
|
Maximum error is 20 % RDG range |
(200~1000)GW/5kV (200~500)GW/2.5kV (100~200)GW/1kV |
(200~1000)GW/10kV (200~1000)GW/5kV (200~500)GW/2.5kV (100~200)GW/1kV |
|
Output short circuit current | ≥8mA | ≥8mA | |
Absorption ratio,Measurement range of polarization index | Measurement range: 0.01 ~99.99 Maximum error: ±(1%RDG+1d) |
Measurement range: 0.01 ~99.99 Maximum error: ±(1%RDG+1d) |
|
Output voltage display error | ±(3%RDG + 1d) | ±(3%RDG + 1d) |