Transformer Loss Tangent Tan Delta Test Set & 10kv 12kv Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Power Factor Tester

Product Details
Customization: Available
After-sales Service: Suppor for Lifelong
Warranty: 1 Year or Extend
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
30000000 RMB
Plant Area
10000 square meters
  • Transformer Loss Tangent Tan Delta Test Set & 10kv 12kv Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Power Factor Tester
  • Transformer Loss Tangent Tan Delta Test Set & 10kv 12kv Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Power Factor Tester
  • Transformer Loss Tangent Tan Delta Test Set & 10kv 12kv Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Power Factor Tester
  • Transformer Loss Tangent Tan Delta Test Set & 10kv 12kv Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Power Factor Tester
  • Transformer Loss Tangent Tan Delta Test Set & 10kv 12kv Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Power Factor Tester
  • Transformer Loss Tangent Tan Delta Test Set & 10kv 12kv Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Power Factor Tester
Find Similar Products

Basic Info.

Model NO.
HM5006
Type
Transformer Tester
Display
Digital
Control
Manual Control
Power Source
AC220V
Anti-Interference
Frequency Conversion
Power
AC 220V±10%
High Output
0.5kv∽10kv/12kv
Precision
2%
Maximum Current
200mA
Capacity
2000va
Self-Excited Power
AC 0V∽50V/15A
Resolving Power
Tgδ: 0.001%.Cx: 0.001PF
Accuracy 1.
△tgδ:±(Reading*1.0%+0.040%)
Accuracy 2
△c X :±(Reading*1.0%+1.00PF)
CVT Range
10∽10000
Accuracy 3
0.1%
Standard
IEC
Certificate
CE, ISO, SGS
Transport Package
Wooden Box with Foam Inside
Specification
350*270*270
Trademark
HMDQ
Origin
Hubei, China(Mainland)
HS Code
9030899090
Production Capacity
500sets/Month

Product Description

Transformer Loss Tangent Tan Delta Test Set  & 10kv 12kv  Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Power Factor Tester 

I. Summary
Tan Delta and Capacitance Dielectric Loss Dissipation Factor test equipment is a basic method in insulation test and effectively detect damp, degradation and partial defect of insulation of electrical equipment. This method is widely used in electric manufacturing, electric equipment installation, connection and preventive test. Measurement on dielectric loss of transformer, mutual inductor, reactor, capacitor, bushing and arrester is the most basic method to test their insulation property.**** fully-automatic anti-interference dielectric loss tester breaks through the traditional bridge testing method and adopts variable frequency power technology, single chip and modernized electrical technology to carry out automatic frequency shift, analog-to-digital conversion and data computing. It features strong anti-interference capacity, high test speed, high precision, automatic digitization and easy operation. It adopts high-power switching power supply, which outputs 45Hz and 55Hz pure sine wave and automatically increase the voltage to a maximum value 10 KV. It can filter 50Hz interference automatically, and it is applicable to the site test of substation and other places with large electromagnetic interference. This methods is extensively applied in dielectric loss measurement of transformer, mutual inductor, reactor, bushing, capacitor, arrester and others equipments in power industry.
Transformer Loss Tangent Tan Delta Test Set & 10kv 12kv Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Power Factor TesterTransformer Loss Tangent Tan Delta Test Set & 10kv 12kv Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Power Factor TesterTransformer Loss Tangent Tan Delta Test Set & 10kv 12kv Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Power Factor TesterTransformer Loss Tangent Tan Delta Test Set & 10kv 12kv Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Power Factor Tester

II. Technical indicators

Accuracy: Cx: ±(reading×1%+1pF)
tgδ: ±(reading×1%+0.00040)
Anti-interference: Variable frequency anti-interference, the above accuracy can be reached under 200% interference. 
Capacitance range: Internal HV: 3pF~60000pF/10kV 60pF~1μF/0.5kV
 External HV: 3pF~1.5μF/10kV 60pF~30μF/0.5kV
 Resolution: Maximum 0.001pF, 4 valid figures. 
tgδ range:unlimited, 0.001% resolution, automatic identification for capacitance, inductance and resistance of three tested articles. 
Test current range: 10μA~1A
Internal HV: Set voltage range: 0.5~10kV
Maximum output current: 200mA
 Buck-bust method: continuous stepless regulation
 Test frequency: 45, 50, 55 single frequency 45/55Hz automatic dual variable frequency
Frequency accuracy: ±0.01Hz
External HV: In case of UST, maximum test current is 1A,and power frequency or variable frequency is 40-70Hz
In case of GST, maximum test current is 10kV/1A,
and power frequency or variable frequency is 40-70Hz
CVT self-exciting low voltage output: Output voltage 3~50V,
output current 3~30A
Measuring duration: About 40s, depending on measuring method
Input power supply: 180V~270VAC, 50Hz/60Hz±1%,

1 Use conditions -15ºC∽40ºC RH<80%
2 Anti-interference Frequency conversion
3 Power AC 220V±10% Allowable generator
4 High output 0.5KV∽10KV Every 0.1kV
Precision 2%
Maximum current   200mA
Capacity 2000VA
5 Self-excited power AC 0V∽50V/15A 45HZ/55HZ 47.5HZ/52.5HZ
55HZ/65HZ 57.5HZ/62.5HZ
Automatic double frequency
6 Resolving power tgδ: 0.001% Cx: 0.001pF
7 Precision △tgδ:±(Reading*1.0%+0.040%)
△C x :±(Reading*1.0%+1.00PF)
8 measuring range tgδ Unlimited
C x 15pF < Cx < 300nF
  10KV Cx < 60  nF
   5KV Cx < 150 nF
   1KV Cx < 300 nF
CVT test Cx < 300 nF
9 CVT range 10∽10000
accuracy 0.1%
Resolving power 0.01
10 Exterior dimension 350(L)×270(W)×270(H)
11 Memory size The 200 group supports U disk data storage
12 Weight 28 Kg
 

III. Performance features
1. The instrument adopts complex number current method to measure capacitance, dielectric loss and other parameters. The measured result is highly accurate and it is easy to realize automatic measurement.  

2. The instrument adopts variable frequency technology to eliminate 50Hz/60Hz power frequency interference. So a reliable data will be reachable even under the strong electromagnetic interference.  
3. The instrument adopts large screen LCD . In the process of testing, Chinese menu prompt is visualized and easy to operate.
4. The instrument is easy to operate and the measuring process is controlled by microprocessor. Once a suitable measuring method is selected, the data measurement will complete automatically under the control of microprocessor.
5. The instrument is designed to be an integrated model with reference capacitor and HV power supply in it, enables site test measurement and reduces site wiring.
7. The instrument is equipped with CVT testing function, which can achieve CVT self-exciting testing without external accessories and measure the capacitance and dielectric loss of C1 and C2 by at a time.
8. GST measurement adopts ivddv technology and avoids unstable data provided by previous GST measurement.
9. The instrument provides low voltage shell function of GST. When the bus of 220kV CVT is grounded, dielectric loss measurement can be conducted for C11 without removing 10 kV GST.
10. The instrument has a function of measuring high-voltage dielectric loss. It can carry out dielectric loss test with over 10kV with the help of voltage transformer or series resonance.
12. The instrument has a ground-fault protection function. In case that the instrument is not grounded or grounded incorrectly, the instrument will refuse to enter into normal procedure and output HV. As for the over-current protection function, it will protect the instrument from damage when the tested article is in a short circuit or breakdowns.
13. The instrument has a function of electric shock protection. When the instrument operator suffers an electric shock due to incaution, the instrument will cut off the HV immediately and thus ensure the security of operator.
Transformer Loss Tangent Tan Delta Test Set &amp; 10kv 12kv Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Power Factor Tester

Transformer Loss Tangent Tan Delta Test Set &amp; 10kv 12kv Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Power Factor TesterTransformer Loss Tangent Tan Delta Test Set &amp; 10kv 12kv Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Power Factor TesterTransformer Loss Tangent Tan Delta Test Set &amp; 10kv 12kv Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Power Factor Tester
Transformer Loss Tangent Tan Delta Test Set &amp; 10kv 12kv Tan Delta and Capacitance Anti-Interference Dielectric Loss Dissipation Power Factor Tester

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier