Dga Dissolved Gas Detection Transformer Oil Test Equipment

Product Details
Customization: Available
Customized: Customized
Structure: Portable
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
30000000 RMB
Plant Area
10000 square meters
  • Dga Dissolved Gas Detection Transformer Oil Test Equipment
  • Dga Dissolved Gas Detection Transformer Oil Test Equipment
  • Dga Dissolved Gas Detection Transformer Oil Test Equipment
  • Dga Dissolved Gas Detection Transformer Oil Test Equipment
  • Dga Dissolved Gas Detection Transformer Oil Test Equipment
  • Dga Dissolved Gas Detection Transformer Oil Test Equipment
Find Similar Products

Basic Info.

Model NO.
HM9890
Certification
ISO
Application
Lab
Type
Measurement Type
Baseline Noise
≤2 *10-13A
Linear
>106
Sensitivity
>5000mv Ml / Mg
Baseline Drift
≤100μV / 30min
Product Name
Transformer Oil Dissolved Gas Analyzer
Transport Package
Wooden Box with Foam Inside
Trademark
HMDQ
Origin
Hubei, China(Mainland)
Production Capacity
100sets Per Year

Product Description

Dga Dissolved Gas Detection Transformer Oil Test Equipment

I. Application

Suitable for the determination of the content of dissolved gas components in insulating oil of electric power system. It can complete 7 kinds of gas components H2, CO, CO2, CH4, C2H4, C2H6, C2H2 (hydrogen, carbon monoxide, carbon dioxide) dissolved in insulating oil at one injection. Full analysis of the content of methane, ethylene, ethane, acetylene, and the minimum detectable concentration of acetylene was 0.06 ppm.

 

II.Specification :
The detection limit: ≤2 × 10-12g / s (n-hexadecane / iso-octane)
Baseline Noise: ≤2 × 10-13A
Baseline Drift: ≤2 × 10-12A / 30min
Linear: ≥106
Adjustable automatic ignition
Settling time: ten minutes
the thermal conductivity detector (TCD):
Semi-diffused structure
Power supply with constant current control mode
Sensitivity: ≥5000mV · ml / mg.
Baseline noise: ≤10μV.
Baseline Drift: ≤100μV / 30min.
Linear ≥ 105
large-screen LCD display:
Clearly show the temperature set point and the brightest, the measured 
values and the protection value
Real-time status display instrument
Automatic ignition
temperature indicators:
Oven: the temperature 5 °C ~ 420 °C Accuracy ± 0.05 °C
Injector: The room temperature 5 °C ~ 420 °C Accuracy ± 0.05 °C
Detector: the temperature 5 °C ~ 420 °C Accuracy ± 0.05 °C
Reformer: The room temperature 5 °C ~ 420 °C Accuracy ± 0.05 °C
the other parameters:
Power: 220V ± 22V, 50Hz,
Power: ≥2 kW

More detailed pictures for transformer oil gas dissolved gas analyzer as below :

Dga Dissolved Gas Detection Transformer Oil Test Equipment
Dga Dissolved Gas Detection Transformer Oil Test Equipment

 

Dga Dissolved Gas Detection Transformer Oil Test Equipment
Dga Dissolved Gas Detection Transformer Oil Test Equipment
Dga Dissolved Gas Detection Transformer Oil Test Equipment
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier