• 60kv/5mA DC Hipot High Voltage Generator
  • 60kv/5mA DC Hipot High Voltage Generator
  • 60kv/5mA DC Hipot High Voltage Generator
  • 60kv/5mA DC Hipot High Voltage Generator
  • 60kv/5mA DC Hipot High Voltage Generator
  • 60kv/5mA DC Hipot High Voltage Generator

60kv/5mA DC Hipot High Voltage Generator

After-sales Service: Life Long Support
Warranty: 1 Year
Type: DC Hipot Tester
Accuracy Grade: 1
Weight: 13kg
Power Source: AC220V
Customization:
Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
HMZGF
Over Voltage Rectify Accuracy
<=1.0%
Ripple Factor
<=0.5%
Altitude
Below 1500m
Transport Package
Wooden Box with Foam Inside
Trademark
hmdq
Origin
Hubei, China(Mainland)
HS Code
9030390000
Production Capacity
500sets/Month

Product Description

60kv/5mA DC hipot  High Voltage Generator

Summary


Newly researched, designed, and manufactured according to "Common technical condition for portable DC HV generator" of China Industry Standard, the HMZGF series DC HV generator is a technology product of new era, suitable for DC HV test on zincoxidearrester, magnetic blow-out arrester, power cable, generator, transformer, and switch in electric power department, scientific research unit, railway station, power plant, chemical plant, etc., a optimal upgrading product in new era.
60kv/5mA DC Hipot High Voltage Generator60kv/5mA DC Hipot High Voltage Generator60kv/5mA DC Hipot High Voltage Generator60kv/5mA DC Hipot High Voltage Generator60kv/5mA DC Hipot High Voltage Generator


Technical parameters

Output voltage(kV):60

Output current (mA):5

Output power (W):300

Charging current (mA):7.5

Case weight (kg):13

Height of multivoltage tube (kg):4

HV polarity

Polarity of negative volt, zero voltage start, continuous adjustable

Work power

AC 220V±10%;50Hz

Voltage measuring accuracy

1.0%(full scale)±1character, max resolution 0.1%kV

Current measuring accuracy

1.0%(full scale)±1character, max resolution 0.1%uA

Over voltage rectify accuracy

≤0.5%

0.75 switch over accuracy

≤1.0%

Ripple factor

≤0.5%

Voltage stability

Random fluctuation, when voltage change of power supply±10% ≤0.5%

Work manner

Intermittent service; 30min of rated load;1.1 times of rated voltage use:10min

Temperature

-10ºC~40ºC

Relative humidity

When at 25ºC,no more than 85%(no condensation)

Altitude

Below 1500m

60kv/5mA DC Hipot High Voltage Generator
60kv/5mA DC Hipot High Voltage Generator
60kv/5mA DC Hipot High Voltage Generator







 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now