100kv 120kv Gas Type Partial Discharge Testing Equipment

Product Details
Customization: Available
Warranty: 1 Year
Type: Impact Testing Machine
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
30000000 RMB
Plant Area
10000 square meters
  • 100kv 120kv Gas Type Partial Discharge Testing Equipment
  • 100kv 120kv Gas Type Partial Discharge Testing Equipment
  • 100kv 120kv Gas Type Partial Discharge Testing Equipment
  • 100kv 120kv Gas Type Partial Discharge Testing Equipment
  • 100kv 120kv Gas Type Partial Discharge Testing Equipment
  • 100kv 120kv Gas Type Partial Discharge Testing Equipment
Find Similar Products

Basic Info.

Load Way
Electronic Load
Display
Digital
Control
Manual Control
Weight
Customized
Power Source
AC220V
Capacity(kVA)
5-300 or Customized
Regulator Capacity(kVA)
5 -300 or Customzied
Working Time
5 Mins or Customized
Output(Kv)
50-300 or Customzied
PC Amount
Less Than 5 PC or Customzied
Wave Distortion
<3
Impedance Voltage
<8
No-Load Current
<6
Certificate
CE,SGS
Standard
IEC
Transport Package
Wooden Box with Foam Inside
Specification
test transformer
Trademark
HMDQ
Origin
Hubei, China(Mainland)
HS Code
9030339000
Production Capacity
50sets/Month

Product Description

100KV Partial Discharge Testing Equipment Sf6 Gas Pd Free Testing Transformer hipot tester  Dielectric Strength  hv test set 

I. Summary

Transformer partial discharge detection device(sf6 high voltage test set) is a necessary test device for power equipment detection and preventive test.
Because of the sf6 high voltage test set excellent insulation and arc extinguishing performance and nonflammability, the six sulfur fluoride gas has been widely applied as a new insulating medium.
After years of efforts, our company has successfully developed a partial discharge detection device for transformers. Compared with the traditional oil immersion light test transformer, this series of the high voltage test set reduce the weight by 20% - 60% (depending on the voltage and capacity grade), and without oil pollution, the voltage level of the single test transformer can reach 300KV. Due to the adoption of the new production technology, the technical performance of the product has been greatly improved, especially for field work and frequent mobile working conditions.

100kv 120kv Gas Type Partial Discharge Testing Equipment

II. Technical indicators and parameters
1.No-load current is 4 to 9%, and impedance voltage is 4 to 10%.
2.Specifications and running time of high voltage test set.
3.More specifications can be customzied 

 
Model YDQ capacity
KVA
Regulator capacity
KVA
Working time
min
ydq-2 1.5 1.5 ≤5
ydq -3 3 3 ≤5
ydq -5 5 5 ≤5
ydq -10 10 10 ≤5
ydq -20 20 20 ≤5
ydq -30 30 30 ≤5
ydq -50 50 50 ≤5
Transformer's technical parameters
 
Input (V) 200 200 400 400 400 400 400
Output
(KV)
50 100 150 200 250 300 400
PC <=3 <=3 <=3 <=3 <=5 <=10 <=10
Impedance% <=8 <=8 <=8 <=8 <=10 <=10 <=10
No-load current% <=6 <=6 <=6 <=6 <=5 <=5 <=5
Distortion% ∠3 ∠3 ∠3 ∠3 ∠3 ∠3 ∠3 

III. Main Parameter for 10kVA/100kV power frequency hipot tester partial dsicharge test equipment
1. gas testing transformer specifictaion
Model No.: HM-YDQW-10kVA/100kV
Phase :single phase
Frequency:50Hz                                       
Rated capacity:10kVA
Input voltage:0.2kV  
Input current:50A       
Output voltage:0~100kV
Output current: 0.1A
Waveform deviation factor:≤3%
Measurement winding voltage ratio:1000:1
pC amount: ≤5PC,at rated 60%voltage,3PC
2.Manual console specification
Model No.:HMTC-100
Phase:single phase                                            
Frequency:50Hz
Rated capacity:10kVA
Input voltage:0.2kV 
Input current:50A       
Output voltage:0~200V
Output current:50A
Waveform deviation factor:≤3%
Insulation level: low voltage input terminal to ground power frequency voltage withstand level 5kV/1min
Insulation level:<0.3%
Noise: ≤60dB
pC amount: ≤5PC,at rated 60%voltage,3PC

3.  Coupling capacitor specification
Mode:  HM-TRF-100-0.01
Rated frequency: 50Hz
Capacity: 500PF±10%
Rated voltage : 100kV                        
Divider ratio: 1000:1
Dielectric loss:<0.5%
Precision: 1.5
Partial discharge: ≤5PC,at rated 60%voltage,3PC
4.
Isolation transformer technical parameterMode: HM-GLB-LNF-100
Rated capacity:10kVA                           
Input voltage:220V
Output voltage:220V
Output current:50A
Rated frequency: 50~60Hz
Number of line:2 line
Quality factor of filter reactor:>70
Partial discharge: ≤5PC,at rated 60%voltage,3PC

100kv 120kv Gas Type Partial Discharge Testing Equipment



IV. Related Products.
 
100kv 120kv Gas Type Partial Discharge Testing Equipment
100kv 120kv Gas Type Partial Discharge Testing Equipment
100kv 120kv Gas Type Partial Discharge Testing Equipment


 
100kv 120kv Gas Type Partial Discharge Testing Equipment
100kv 120kv Gas Type Partial Discharge Testing Equipment
100kv 120kv Gas Type Partial Discharge Testing Equipment



100kv 120kv Gas Type Partial Discharge Testing Equipment
100kv 120kv Gas Type Partial Discharge Testing Equipment
100kv 120kv Gas Type Partial Discharge Testing Equipment


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier