• on-Line Partial Discharge Tester for Cable, Gis, Circuit Breaker Monitoring
  • on-Line Partial Discharge Tester for Cable, Gis, Circuit Breaker Monitoring
  • on-Line Partial Discharge Tester for Cable, Gis, Circuit Breaker Monitoring
  • on-Line Partial Discharge Tester for Cable, Gis, Circuit Breaker Monitoring
  • on-Line Partial Discharge Tester for Cable, Gis, Circuit Breaker Monitoring
  • on-Line Partial Discharge Tester for Cable, Gis, Circuit Breaker Monitoring

on-Line Partial Discharge Tester for Cable, Gis, Circuit Breaker Monitoring

After-sales Service: Life Long Support
Warranty: 1 Year
Type: Partial Discharge Detector
Power Source: AC220V
Product Name: Partial Discharge Detector
Detection Methods 1`: Ae
Customization:
Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
HM9001
Detection Methods 2`
Tev
Detection Methods 3`
UHF
Detection Methods 4`
Hf
Lithium Battery Pack
24V/5ah
Synchronization
External Synchronization AC10~380V, with Virtual S
Wireless Synchronization
AC10~380V
System Platform
Wince6.0, 1 Network Port, 1 USB Port, Support Flas
Transport Package
Wooden Box with Foam Inside
Trademark
HMDQ
Origin
Hubei, China(Mainland)
Production Capacity
500sets/ Month

Product Description

on-Line Partial Discharge Tester for cable, GIS, circuit breaker monitoring

I. Product overview    

tThis product can be widely used in the partial discharge detection of power systems, including high-voltage switchgear, ring main unit, voltage/current transformer, transformer (including dry-type transformer), GIS, overhead lines, cables and other equipment insulation state detection, through the following indicators to measure the degree of discharge of electrical equipment:
Partial Discharge Intensity Detection: The intensity of partial discharge is characterized according to the maximum value (dB) in the discharge pulse sequence by measuring the discharge signal within 1 power frequency cycle.
Partial discharge frequency detection: By measuring the discharge signal within 1 power frequency cycle, the discharge pulse is extracted and the frequency of partial discharge is characterized according to the number of discharge pulses.


on-Line Partial Discharge Tester for Cable, Gis, Circuit Breaker Monitoring

II.Technical parameters  
TEV measurement AE measurement
Measuring range 0dB~60dB Measuring range 0dB ~ 60dB
Resolution 1dB Resolution 1dB
Precision ±1dB Precision ±1dB
Maximum pulse
per cycle
1400 Frequency range 20~200 kHz
Measurement
frequency bands
3~100MHz    
AA ,AA1,AA 2measurement UHF measurement
Measuring range 0dB~60dB Detection bands 300~2000MHz
Resolution 1dB Measuring range 0dB~60dB
Precision ±1dB Sensitivity <1dB
Sensor center
 frequency
40 kHz Sensor bands 300~2000MHz
HFCT measurement
Sensor transmission impedance 5mV/mA
Frequency of detection 1~30MHz
Sensitivity ≤50pC
hardware
Apperance ABS
Display 4.3 inch RGB LCD screen with resolution 800*480
Sampling accuracy 12bit
Synchronization mode Synchronization within the country
Connector USB port (also charger input)  
Earphone 8 ohms minimum
SD card 16G~64G as standard
Built-in battery 3.7V/10000mAh lithium battery
Working time Approximately 12 hours
Charger DC 5V/3A 
Temperature -20~50ºC
Humidity 20%~85% relative humidity
Volume, weight 210*100*35(mm) 0.4KG(host)


on-Line Partial Discharge Tester for Cable, Gis, Circuit Breaker Monitoring

 III.Product Features
1. Configure different sensors to realize the partial discharge detection of almost all high-voltage electrical equipment;
2.Provide a variety of discharge patterns such as time-domain waveform, PRPD, PRPS, etc., to realize the analysis of different discharge types;
3.Humanized man-machine interface facilitates data management of different devices;
4.Built-in ultrasonic sensor and transient ground voltage (hereinafter referred to as TEV) sensor, which can be connected to special sensors such as transformers, GIS, overhead lines, cables, etc.;
5.The non-invasive detection method does not require power failure during the test process, and there is no need to configure an additional high-voltage source, which is more convenient to use than the traditional pulsed partial discharge detector;
6.The test bandwidth range is 30kHz ~ 2.0GHz, which is suitable for the detection principle of various frequency bands;

 
on-Line Partial Discharge Tester for Cable, Gis, Circuit Breaker Monitoring
on-Line Partial Discharge Tester for Cable, Gis, Circuit Breaker Monitoring
on-Line Partial Discharge Tester for Cable, Gis, Circuit Breaker Monitoring







 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now