10kv Insulation Resistance Megohmmeter Tester with Pi and Dar Measuring

Product Details
Customization: Available
After-sales Service: Long Life
Warranty: 1 Year or Extended

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
30000000 RMB
Plant Area
10000 square meters
  • 10kv Insulation Resistance Megohmmeter Tester with Pi and Dar Measuring
  • 10kv Insulation Resistance Megohmmeter Tester with Pi and Dar Measuring
  • 10kv Insulation Resistance Megohmmeter Tester with Pi and Dar Measuring
  • 10kv Insulation Resistance Megohmmeter Tester with Pi and Dar Measuring
  • 10kv Insulation Resistance Megohmmeter Tester with Pi and Dar Measuring
  • 10kv Insulation Resistance Megohmmeter Tester with Pi and Dar Measuring
Find Similar Products

Basic Info.

Model NO.
HM2306
Type
Insulation Resistance Tester
Display
LCD
Control
Manual Control
Weight
14kgs
Power Source
Alkaline Battery
Output Voltage
500V, 1000V, 2500V, 5000V.10000V
Short Circuit Current
≥10mA
Measure The Voltage (Kv)
Nominal Voltage *(1±10%)
Capacitance Cx
0.01-10UF
Dar.Pi Measuring Range
Measuring Range: 0.01 ~9999.99
Output Voltage Display Error
±(3%Rdg + 1d)
Anti-Interference Capability
50 Ma(Induced Voltage 2000V)AC 50Hz
Insulation Resistance
50 M (10kv)
Withstand Voltage
AC 3kv 50Hz 1min
Power Supply
Lithium Battery
Charging
AC 220V (1±10%)
Certificate
CE, SGS
Standard
IEC61010-1:2001
Model Name
Insulation Resistance Tester
Type No
Hm2306
Transport Package
Wooden Box with Foam Inside
Specification
38.5. x 29.8. x 19.6.
Trademark
HMDQ
Origin
Hubei, China(Mainland)
HS Code
9030332000
Production Capacity
500sets/Month

Product Description

10kv Insulation resistance megohmmeter tester with PI and DAR measuring 


1.Overview

  The rapid development of modern industry, the insulation test of high-voltage equipment puts forward higher requirements, and the traditional measurement methods will face severe tests. With the large-scale application practice of optical fiber in intelligent substation, HM2306 10KV insulation resistance tester has good insulation and anti-interference ability, high measurement accuracy, easy miniaturization, and extremely low failure rate, which has received extensive attention. It is widely used  to solve the evaluation of electrical insulation quality of large high-voltage transformers, electric motors, generators, long-distance power cables and tubular busbars under high-voltage substation and power plant on-site strong interference.


2.Technical specifications
Safety specifications
-IEC 61010-1 CAT.IV 600V pollution level 2
-IEC 61326, EMC specification: electrical equipment for testing, control and inspection
-IEC60529 IP64 (outer box closed state)

The instrument is in line with international safty standards IEC610101:2001.
This instrument performs standard Q/WKD10.
-Insulation resistance: 50 MW  (between line and shell)
-Withstand voltage: AC, 10kV, 50Hz, 1min (measuring line and shell)
-Temperature and humidity: -30ºC ~ +60ºC  85%RH
-Storage temperature & humidity: -15ºC ~ +55ºC  90%RH
-Battery powered: two group battery charging together, 16V lithium ion rechargeable battery 2600mAH ,7.4v 2200mAH or charging side measurement.
Power charge:220V±10%,50/60HZ
-Size : 38.5. x 29.8. x 19.6.
-Weight: 4.5kg
-5.7inch screen display, resolution: 320*240
-Display mode: digital and analog pointer double display
10kv Insulation Resistance Megohmmeter Tester with Pi and Dar Measuring
10kv Insulation Resistance Megohmmeter Tester with Pi and Dar Measuring
10kv Insulation Resistance Megohmmeter Tester with Pi and Dar Measuring10kv Insulation Resistance Megohmmeter Tester with Pi and Dar Measuring
3.Measurement accuracy

Rated voltage(kV) 0.25,0.5,1,2.5,5
Measurement voltage(kV) Rated voltage×(1±10%), The load resistance is not less than 1% of the test range
Minimum error is 5%
RDG range
(0.001~100)GW/5kV
(0.001~200)GW/2.5kV
(0.001~50)GW/1kV
(0.001~20)GW/0.5kV
(0.001~5)GW/0.25kV
(0.001~100)GW/10kV
(0.001~200)GW/5kV
(0.001~200)GW/2.5kV
(0.001~100)GW/1kV
(0.001~20)GW/0.5kV
Maximum error is 10 %
RDG range
(100~200)GW/5kV
(5~10)GW/0.25kV
(100~200)GW/10kV
 (100~200)GW/5kV
Maximum error is 20 %
RDG range
(200~1000)GW/5kV
(200~500)GW/2.5kV
(100~200)GW/1kV
(200~1000)GW/10kV
(200~1000)GW/5kV
(200~500)GW/2.5kV
(100~200)GW/1kV
Output short circuit current ≥8mA ≥8mA
Absorption ratio,Measurement range of polarization index Measurement range: 0.01 ~99.99
Maximum error: ±(1%RDG+1d)
Measurement range: 0.01 ~99.99
Maximum error: ±(1%RDG+1d)
Output voltage display error ±(3%RDG + 1d) ±(3%RDG + 1d)



5. Related Products.

10kv Insulation Resistance Megohmmeter Tester with Pi and Dar Measuring
5. More information
10kv Insulation Resistance Megohmmeter Tester with Pi and Dar Measuring10kv Insulation Resistance Megohmmeter Tester with Pi and Dar Measuring10kv Insulation Resistance Megohmmeter Tester with Pi and Dar Measuring10kv Insulation Resistance Megohmmeter Tester with Pi and Dar Measuring10kv Insulation Resistance Megohmmeter Tester with Pi and Dar Measuring10kv Insulation Resistance Megohmmeter Tester with Pi and Dar Measuring





 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier