Hipot Tester Hipot Test Set AC Resonance Withstand Voltage Test System

Product Details
Customization: Available
Type: Universal Testing Machine
Accuracy Grade: 1.5
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
30000000 RMB
Plant Area
10000 square meters
  • Hipot Tester Hipot Test Set AC Resonance Withstand Voltage Test System
  • Hipot Tester Hipot Test Set AC Resonance Withstand Voltage Test System
  • Hipot Tester Hipot Test Set AC Resonance Withstand Voltage Test System
  • Hipot Tester Hipot Test Set AC Resonance Withstand Voltage Test System
  • Hipot Tester Hipot Test Set AC Resonance Withstand Voltage Test System
  • Hipot Tester Hipot Test Set AC Resonance Withstand Voltage Test System
Find Similar Products

Basic Info.

Model NO.
HMCXZ
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Digital
Control
Computer Control
Weight
0-100Kg
Power Source
220V/380V
Model No.
Hmcxz
Product Name
AC Resonant Test System
Output Frequency
30 -300Hz
Resonant Voltage Waveform
Sine Wave, Thd ≤ 1%
Full Load Working Time
Continuous Working Time 60mins
Warranty
1 Year
Standard
ISO
Output Voltage
Customsize
Capacitance
Customsize
Transport Package
Wooden Box with Foam Inside
Specification
customsize
Trademark
HMDQ
Origin
Hubei, China(Mainland)
HS Code
9031809090
Production Capacity
100sets/Year

Product Description

I. Product Description 
 
Series Variable Frequency Resonant AC Hipot Test Set mainly aimed at consumers 10kV,35kVcable,110kV,under compression experiment design and manufacture of substation exchanges.
Reactor of Resonant Test Device using separate design not only can meet high voltage, low current equipment test conditions request, and can satisfy the consumers 10kV cable such as low voltage ac pressure test requirements. Resonant Test Device has a wide scope, earth, city and county level shall high voltage test departments and electricity installation, Resonant Test Device repair engineering unit ideal compression test equipment.
Variable Frequency Series High Voltage AC Resonant Test System is mainly composed of Variable Frequency Power,Exciting Transformers,Reactors, Capacitive Dividers.

 
II. Series Variable Frequency Resonant AC Hipot Test Set Advantage 
1) Placed way: the placement of variable frequency power for longitudinal and transverse, especially suitable for field operation and observe.

2) Shockproof protection: internal and external have special damping rubber support foot and protect aluminum boxes, which can effectively slow motion and lifting the bumpy transport the shock. Ensure the inverter power long-term stability and reliability.

3) Parameter display: touch or external mouse LCD interface display system.
Can show resonance voltage (namely test before setting goals voltage), test frequency, measure frequency, low-pressure voltage, low voltage electric current, voltage time, over-voltage protection, over-current protection, flash winding protection, phase booster and stage timing, operation mode switch, capacitor, inductance, frequency swap calculation, parameters, still can show inquiry on frequency curve, voltage curve can intuitivey judgment when trials resonance frequency accurately and stability.

4) Parameter Settings: big screen touch LCD backlit and external mouse directly in completing various parameters Settings. But on the initial frequency, termination frequency, starting voltage, phase booster and timing, measuring bleeder variable ratio, incentive change ratio, over-voltage protection, over-current protection, flash winding protection, test mode, capacitance inductance frequency swap calculation, parameter setting tips, and help parameters Settings or choice.

5) Test mode: touch screen and external mouse operation, there is automatic and semi-automatic, manual three operating status. With pressor, tuning (including manual, automatic), subsection pressurized and timing, running status, pattern switching, troubleshooting tips, capacitance inductance frequency swap computing functions, etc.

6) Protection function and information clew: having high-pressure over-voltage protection, low-pressure over-current, over-current protection, as well as detuning protection, zero, shem winding protection, emergency stop, undervoltage protection multiple protection function.

7) Automatic voltage function: system according to the test voltage or manually set of automatic tracking and boost results, stable test voltage, voltage stability can amount to 1.0%.

8) FM range and frequency resolution all can set: FM range set:30~300Hz,45~100Hz,200-300Hz, on-demand setting, can accelerate tuning process; The frequency resolution, according to the needs, presetting 0.1 Hz, efficiency and tuned in tuned balance between accuracy obtained optimization.

9) Frequency adjustment is divided into thick harmonic fine tuning, and automatic resonant point, guarantee for trials in the whole experiment resonant frequency process does not happen drift.

10) Storage measuring datas and print.

III.Series Variable Frequency Resonant AC Hipot Test Set Parameter
-Rated Capacity: 20-20000kVA;
- Output Voltage: 0-1000KV
- Output Current:0-200A
- Output frequency: 30-300Hz;
- Input Power: 220V/380V ±10 %single phase, 50Hz
- Waveform distortion rate: output voltage distortion ≤ 1%;
- Working time: 30mins under rated load;Cable testing: continuous 60 minutes under rated load;
- Temperature rise: ≤65K under rated load;
- Working Temperature: -15ºC~+45ºC
- Quality factors: Q ≥ 50; Cable testing Q ≥ 30 (depend on load).
- Stability: Over-current/over-voltage/Flashover protection;Auto Time;Touch Screen;
- Accuracy: RMS 1.5 (0.5/1.0/1.5)


IV. Series Variable Frequency Resonant AC Hipot Test Set Application

Hipot Tester Hipot Test Set AC Resonance Withstand Voltage Test System


Similar product
Hipot Tester Hipot Test Set AC Resonance Withstand Voltage Test System



Hipot Tester Hipot Test Set AC Resonance Withstand Voltage Test System

Hipot Tester Hipot Test Set AC Resonance Withstand Voltage Test System

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier