Secured Trading Service

Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester

Wuhan Goldhome Hipot Electrical Co., Ltd.
  • Audited Supplier
  • 9 yrs
  • leading factory

Contact Supplier

Product Highlights

  • High Precision Measurement: Voltage and current accuracy up to +0.2%, power accuracy +0.5% for reliable transformer testing.
  • All-in-One Functionality: Replaces two instruments by measuring capacity, load loss, no-load loss, and impedance voltage simultaneously.
  • Portable and Lightweight: Compact design weighing only 2.5kg with dimensions 32x25x12cm for easy field transport.
  • Extended Battery Life: Built-in rechargeable battery supports over 100 continuous transformer measurements without external power.
  • Automatic Data Correction: Automatically corrects waveform, temperature, voltage, and current for precise test results.
  • Integrated Thermal Printer: Panel-type printer allows immediate on-site printing of test results for quick documentation.
  • Large LCD Display: 320x240 high-brightness screen with adjustable brightness and full menu for clear visibility.
  • OEM and ODM Services: Flexible customization options available including full customization and minor adjustments.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester

Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester
Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester pictures & photos
Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester
Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester pictures & photos
Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester
Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester pictures & photos
Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester
Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester pictures & photos
Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester
Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester pictures & photos
Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester
Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester pictures & photos
Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester
  • Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester
  • Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester
    Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester
  • Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester
    Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester
  • Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester
    Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester
  • Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester
    Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester
  • Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester
    Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester
  • Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester
    Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester

Find Similar Products

Product Description

Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester

Summary

HM5003 transformer performance tester is designed for high precision instrument for measuring the parameters of the transformer capacity. This product uses color large screen LCD display, Chinese display, simple and quick menu type operation, man-machine interface is friendly. The instrument comes with a high efficiency rechargeable battery, which can work without external power supply. The battery is fully charged at one time and can continuously measure more than 100 sets of transformers. In addition, the instrument can provide precise 50Hz three-phase sine wave AC power supply test, measurement of load loss in transformer capacity and the transformer does not need external power supply and test three-phase voltage regulator, current booster and other auxiliary equipment, which greatly improves the efficiency of your work.

The instrument is multi-functional measuring instrument, equivalent to the usual two test instruments: active transformer characteristic tester + transformer characteristic parameter tester. It can measure a series of power frequency parameters, such as capacity, type, no-load current, no-load loss, load loss, impedance voltage and so on.

The utility model has the advantages of small size, light weight, high measurement accuracy, good stability, simple operation, etc.. It can replace the former method of measuring transformer loss and capacity by using multi table method. The connection is simpler, the test and record are more convenient, and the work efficiency has been greatly improved.

Functional characteristics

1.Measure the transformer load current, load loss, short-circuit voltage, short circuit (load) losses, capability.

2.Three measurement Methods.


3.Do three-phase transformer no-load, load test, the instrument can automatically determine the wiring is correct, and shows three-phase voltage and current vector map.

4.Single machine can do the following 100KVA distribution transformer full load current experiment; in one third of the rated current, complete 250KVA distribution transformer
load the following test (in one third of the rated current, the instrument can be converted
to load loss under rated current parameters, the machine is mainly used in the test bed
with integrated supporting the use of transformers.


5.All the related test results are automatically corrected. Instrument can automatically such as: the waveform correction, temperature correction, non-rated voltage correction,
calibration, and other non-rated current correction, so that more accurate test results.

6.320x240 large screen, high brightness LCD display, full Chinese menu and operations
to achieve prompt and friendly man-machine dialogue, touch buttons make the
operation more convenient, wide LCD with brightness adjustment, can be adapted to
the various summer and winter season.

7.Comes with real-time clock, automatically recording test date, time, the preservation of
favorable results, management.

8.Panel-type thermal printer, the scene quickly print test results.


9.Data (test sample set, the measurement results, the test of time, etc.) with power-down storage and browsing features, you can store 500 set of experimental results with
computer on-line data transfer.


10.Allows an external voltage transformer and current transformer for extended range of measurement, any measurable parameter is the test product.
Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester

Main technical indicators

1 .Built-in power output range
Voltage: 0 ~ 10V
Current: 0 ~ 10A
2.Characteristic test power input range
Voltage: 0 ~ 750V
Current: 0 ~ 100A
3.Test accuracy
Voltage and current: + 0.2%
Power: + 0.5% (Cos phi >0.1), + 1% (0.02<Cos phi <0.1)
4.Working temperature
-20ºC~+60ºC
5.Charger power requirements:  AC160V ~ 265V
6.Insulation
1) Capacity testing, voltage and current inputto shell insulation resistance ≥100MΩ
2) Charging power supply input to shell frequency withstand 2KV(RMS), 1 minute.
7.Size: 32cm * 25cm * 12cm
8. Weight: 2.5 kg
Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester
Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester
Full-Automatic Transformer Short Circuit Loss and Capacity Test Load/No-Load Characteristic Tester

 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR259015". Items marked "verified" are certified.

Watch Video
Watch Video
Wuhan Goldhome Hipot Electrical Co., Ltd.
Wuhan Goldhome Hipot Electrical Co., Ltd.
Wuhan Goldhome Hipot Electrical Co., Ltd.
Wuhan Goldhome Hipot Electrical Co., Ltd.
Wuhan Goldhome Hipot Electrical Co., Ltd.
Wuhan Goldhome Hipot Electrical Co., Ltd.
Wuhan Goldhome Hipot Electrical Co., Ltd.
Wuhan Goldhome Hipot Electrical Co., Ltd.

About Our Factory & Business Background

Address
No. A25-1 Huading Industrial Park, Hannan District, Wuhan, Hubei, China
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shanghai Port; Ningbo Port; Shenzhen Port; Guangzhhou Port
verified Minimum Order Quantity
1 Set
verified Supply Chain Partners
10

Our Production Capability & Technical Expertise

Main Products
AC Resonant Test System, AC/DC Hipot Tester, Circuit Breaker Analyzer, Hv Test Set, Power Frequency Hipot Tester, Transformer Tester, AC Dielectric Test Set, Partial Discharge Test Set, High Voltage Test Set, Primary Current Injection Test Set
verified Production Lines
4
verified Production Machines
Cutting Machine, Lathe, Drilling Machine, Milling Machine, Welding Machine, Wire Winding Machine
verified QA/QC inspectors
2 people
verified Inspection Type for Finished Products
100% inspection(Visual inspection & Function inspection)
verified Inspection Method for Finished Products
Have instructions and uniformly followed
verified Customization Options
Customization from Samples, Customization from Designs, Full Customization, Minor Customization, Flexible customization
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
3 people
verified Traceability of Raw Materials
Yes
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Export Year
17 Years
verified Main Markets
North America, South America, Europe, Southeast Asia/ Mideast
verified Annual Export Revenue
12,540,865 RMB
verified Number of Foreign Trading Staff
3
verified Overseas Agent/Branch
No
verified New Products Launched in Last year
Yes

FAQ

What parameters can this tester measure?
It measures transformer capacity, type, no-load current, no-load loss, load loss, and impedance voltage.
Does the device require an external power supply?
No, it features a built-in high-efficiency rechargeable battery for operation without external power.
How many test results can be stored?
The instrument can store up to 500 sets of experimental results with power-down storage capability.
Is customization available for this product?
Yes, we offer OEM, ODM, and flexible customization options based on samples or designs.
What is the minimum order quantity?
The minimum order quantity is 1 set.
What is the lead time for production?
The average lead time is within 15 workdays for both peak and off-peak seasons.
Can the tester print results on-site?
Yes, it comes with a panel-type thermal printer for quick printing of test results.
What is the measurement accuracy?
Voltage and current accuracy is +0.2%, and power accuracy is +0.5% for Cos phi >0.1.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now