50kv 100kv AC DC High Voltage Hv Capacitance Divider for High Voltage Measuring

Product Details
Customization: Available
After-sales Service: Life Time Support
Warranty: 1 Year or Extended
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
30000000 RMB
Plant Area
10000 square meters
  • 50kv 100kv AC DC High Voltage Hv Capacitance Divider for High Voltage Measuring
  • 50kv 100kv AC DC High Voltage Hv Capacitance Divider for High Voltage Measuring
  • 50kv 100kv AC DC High Voltage Hv Capacitance Divider for High Voltage Measuring
  • 50kv 100kv AC DC High Voltage Hv Capacitance Divider for High Voltage Measuring
  • 50kv 100kv AC DC High Voltage Hv Capacitance Divider for High Voltage Measuring
  • 50kv 100kv AC DC High Voltage Hv Capacitance Divider for High Voltage Measuring
Find Similar Products

Basic Info.

Model NO.
HMFRC
Type
High Voltage Divider
Accuracy Grade
AC 1.0%, DC 0.5%
Display
Digital
Control
Manual Control
Weight
8kg
Power Source
AC220V
Voltage Class
50-500kv
Divider Rato
1:1000
Humidity
<85%
Accurancy
1.0,0.5
Product Name
High Voltage Divider
Standard
CE
Function
Display RMS, Peak,etc or Customized
Voltage Meter
Includes
Material
Resistors or Capacitors Build-in
Partial Discharge Value
Customized, up 2PC
Transport Package
Wooden Box with Foam Inside
Specification
220*220*600
Trademark
HMDQ
Origin
Hubei, China(Mainland)
Production Capacity
500sets/Month

Product Description

50KV 100KV ac dc high voltage HV capacitance divider for high voltage measuring 

I. Summary
HMFRC series high Voltage Divider (Kilovoltmeter)is a universal high Voltage measuring instruments which can be used to test Power frequency AC high voltage and DC high voltage for electric power systems, electrical appliance, electronic equipment manufacturing sector. It includes high voltage testing part & low-voltage measuring instruments. The low-voltage & high voltage part can work separately, so it is of safety and reliability. It is the upgrading products of static high voltage meter, packed with aluminum alloy case for portable.



II. Main Technical Parameters 
1.Testing Accuracy: AC 1.0%, DC 0.5%
2. Divider ratio: 1:1000
3. Condition: Temperature 0~40ºC; Humidity:<85%
4. Voltage class: 50-500KV


50kv 100kv AC DC High Voltage Hv Capacitance Divider for High Voltage Measuring


50kv 100kv AC DC High Voltage Hv Capacitance Divider for High Voltage Measuring

III. Methods of use
1.Please connect with the Divider and DUT(Device under   Testing)
2. The Ground wire will be connected with the Socket of Divider Base;
3. The grounding clip must be absolutely connected to ground.
4. The high voltage wire connect with the Output showed on base, then fasten High voltage wire with the screw bolt.
5. Connecting the Multimeter with the Multimeter wire;
6. Switching the Multimeter conversion button to AC200V or DC200V( "V" to be read as "kilovolt" as numerical reading).
7. Start to connect High Voltage, the digital instrument will directly show the testing data. (Note: The staffs are not allowed to close the High Voltage Arm to avoid danger during testing).

8. After completing testing, firstly cut off supply power of HV equipment and the staffs can allow to enter the testing field until the Multimeter show the figure "0".

 
IV. Maintain
1.Before using the instrument,observation of appearance in a priority, if there is damaged and the display is correct. If the equipment is not used for a long-term, the user should also check the wire terminal whether there is a corrosion and aging. 
2. After completing the testing, should remove the instrument terminal on the connection, turn off the power, keep the divider surface clean and place inside the aluminum box.


V. Caution
1.Make sure there will not be junk within 2.5 meters around the High Voltage divider, keep enough space between the Mutilmeter and the Divider.
2.The staffs are not allowed to close the High Voltage Arm  during testing.

3.The divider should be placed in dry place and safekeeping.


VI. Packing List
Divider     1 pc
Multimeter 1 pc
Connection line 1 pc
Test Report 1 copy

50kv 100kv AC DC High Voltage Hv Capacitance Divider for High Voltage Measuring50kv 100kv AC DC High Voltage Hv Capacitance Divider for High Voltage Measuring
50kv 100kv AC DC High Voltage Hv Capacitance Divider for High Voltage Measuring



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier