Internal and External Optional, External Synchroni
Sync Input Range
10V --- 220V
Linearity Error of The Range Stalls
Less Than 5% ± 1PC
Transport Package
Wooden Box with Foam Inside
Trademark
HMDQ
Origin
Hubei, China(Mainland)
Production Capacity
500sets/ Month
Product Description
partial discharge detector for cable, GIS
I.Product overview Portable partial discharge detector is a special instrument for measuring and analyzing insulation performance of power equipment. it is one off-line partial discharge detector.
This system adopts modern electronic and computer integrated technology, realize signal(analog, electronics, digital) amplification , filtering, data acquisition, data processing, graphic display, and automatic test report generation, so as to complete the partial discharge measurement and analysis. This instrument is easy to carry, and with fast measurement, strong anti-interference ability, which is easy to use on site. Its configuration software is with functions such as time-domain graphics, 2D, 3D statistic map, alarm history, history largest, pulse counting. The software can also enquire and analyse a phase waveform in detail and the window can be zoomed in and out at will. It can also analyze the spectrum of the data, analyze the spectral content of the discharge waveform, make the discharge waveform more comparable, and comprehensively analyze the test data to reduce the influence of the non-stability factors on the test results.Automatic or manual record are used to keep test data and transient discharge waveform which can provide reference for later data analysis. II.Technical parameters
1. Power Supply 220V AC -5% to +10% Freq: 50Hz±5% 2.Environment Temperature : -5ºC~40ºC Humidity: < 85% 3.Security Insulation resistance:> 2MΩ Leakage: < 3.5mA Dielectric strength: the power line right into the chassis can withstand 1500V (50HZ RMS) 1min of the voltage test. 4.Shape and weight size: 300x350x90 (mm) weight:4kg 5. Host function index CH:4; Sensitivity: 0.1pc; Measurement band:3dB bandwidth of 10kHz-1000kHz Multi-file any combination;
Lp:10K,20K,40K,80K; Hp:100K,200K,300K,1000K; Gain Range: -20 dB ∽ +40 dB fourth gear can be coarse to fine-tune;
Sampling accuracy: 12Bit; Sample Rate:10M /sec.; External Voltage Monitoring: RMS voltage, 14-bit A / D accuracy; Synchronization: internal and external optional, external synchronization: 30HZ-600HZ automatic synchronization; Sync Input Range: 10V --- 220V; Linearity error of the range stalls <5% ± 1PC;
6.External Calibrator(CE) Output standard pulse rising edge <60nS Standard pulse output falling edge> 100uS Standard pulse voltage: 0.5V,1.0V,2.0V,5.0V Calibration capacitors:10pF,100pF Output resistance < 100Ω