Basic Info.

Model NO.
HM-KC60
Display
LCD Screen
Weight
25kg
Max Output Max Voltage
60kv
Max Output Max Current
600mA
Continous Power
1000W
Display Error
±1.5%
Working Voltage
AC 220V
Frequency
50Hz
Rh
90%
Resolution Ratio
640*480
Measuring Size
450*320*340mm
Standard
IEC
Certificate
CE, ISO
Transport Package
Wooden Box with Foam Inside
Specification
HM-KC 60
Trademark
HMDQ
Origin
Hubei, China(Mainland)
HS Code
9030899090
Production Capacity
300sets/Month

Product Description

 Cable Fault Burning Intrument


I. Introduction 

60kV/600mA cable burning instruments  cable thumper can emit a DC constant current voltage, forming a point heat source when the insulation is not good, and changing the insulation condition by the point heat source To achieve our ideal test status. A large number of practices have proved that this method is very effective in solving connector failures and other difficult faults. KC-60 CNC digital DC withstand voltage burn-through source (DC high voltage constant current power supply) is mainly used for high voltage cable insulation defects and high resistance leakage. The burn-through of the fault point causes the insulation resistance value of the poor insulation point and the high-resistance fault point to be greatly reduced, and the fault test condition is reached (the high voltage pulse can fully discharge). At the same time, it can also be used as a DC high-voltage power supply, which can perform DC withstand voltage tests on cables, capacitors, motors, porcelain bottles, etc. Used for DC withstand voltage of high-voltage electrical equipment, especially suitable for burn-through of high-resistance fault points of power cables, reducing the resistance at fault points.
Cable Fault Burning Intrument


1.DC withstand voltage test Can output 60kV DC voltage, can be used for DC withstand voltage test of high voltage cables and electrical equipment.

2.Burn-through cable failure points are particularly effective for breakdowns where high-voltage pulses such as high flashover resistance and intermediate connector water and moisture are difficult to penetrate..


Cable Fault Burning Intrument


II.Main Parameter 

  1. Max output max voltage:60KV
  2. Max output max current:600mA
  3. Continous power:1000W  
  4. Display error:<±1.5%
  5. Working voltage:AC 220V±10%  50Hz
  6. Working temperature :-20ºC - 50ºC
  7. RH:≤90%  
  8. Display:5.6cun color LCD screen,resolution ratio is 640*480
Cable Fault Burning Intrument

Cable Fault Burning Intrument


III. Functions and features:
 
  1. Used for burn-through of high voltage cable with poor insulation points and high resistance leakage fault points to reduce its insulation resistance and meet the requirements of fault testing.
  2. Adopting switching power supply technology, PWM pulse width modulation, adjusting output voltage and current, super audio full-bridge inverter, voltage doubler rectification, small ripple coefficient, no noise.
  3. Using single-chip industrial control technology, the burn-through voltage is automatically adjusted down as the insulation resistance value is reduced, the burn-through current is greatly increased, and the fault of the insulation failure point and high-resistance leakage point of the cable in a short time (maximum current 600mA).
  4. Large-scale integrated circuit and digital control technology are used to realize multiple safety protection functions such as burn-in automatic shutdown, automatic overload protection, high temperature automatic alarm, etc., the maximum voltage, maximum current, and limit power are triple-limited;
  5. Professionally designed high-voltage output socket and high-voltage plug-in connector. The length of high-voltage cables can be determined according to user needs, and it is easy to replace..
  6. Internally adopts high-precision digital detection technology and high-tech insulation technology, and uses a large-screen color liquid crystal as an information terminal, which can clearly display the real-time change curves of voltage and current during burn-through, and realize real-time collection of voltage and current values. And record the test time.
  7. The high-voltage part is packaged with solid insulation materials, which can be used in low-pressure and humid environments at high altitudes..
  IV . Related Products
Cable Fault Burning Intrument

Cable Fault Burning Intrument
Cable Fault Burning IntrumentCable Fault Burning Intrument



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier